Powermatic 201 Manual De Usuario

Descargar
Página de 40
 
 13
If it is too high, a shallow "clip" will occur at each end of 
the board.  If it is too low, stock will not feed through. 
 
Use a bed and feed roll gauge to set the full length of 
the pressure bar to be .000-.001" (.02mm) above the arc 
of the cutterhead.  Figure 13 shows the height 
adjustment screw (C) and the spring tension adjustment 
screw (D) for the pressure bar. This initial setup is a 
starting point and final adjustment may have to be made 
during a test cut. 
 
 
OUTFEED ROLL
 
 
The outfeed roll is of smooth, one-piece construction to 
help avoid marring the finished surface of the material 
being cut.  Its function is to continue to feed the material 
through the machine after it leaves the infeed roll.  The 
correct free position setting is 1/32" (.8mm) below the 
arc of the cutterhead knives. 
 
Use a bed and feed roll gauge to check the outfeed roll 
in the same manner as the infeed roll.  Adjust as 
necessary using the screws shown in Figure 13. 
 
 
TABLE ROLLS 
 
The Model 201 Planer has two table rolls which help 
reduce friction of the stock on the table as it feeds 
through the machine.  It is not possible to give exact 
height setting of the table rolls because each type of 
wood behaves differently.  As a general rule, however, 
when planing rough stock, the table rolls should be set 
high and when planing smooth stock the table rolls 
should be set low.  Height should should normally range 
between .005" to .015".  
The planer is equipped with a quick set table roll 
adjustment.  With a single lever, you can raise the rolls 
from their finishing board height to a roughing board 
height. See Figure 14.  The range is 0.00 to .060” 
To adjust the height of the table rolls, loosen the handle 
(A) and turn the lever (B).  Re-tighten the handle to lock 
the setting. 
 
 
If the table rolls should need further adjustment: 
 
1. 
Position the lever (B-Fig. 14) to zero setting.   
 
2.  Use a bed and feed roll gauge and zero the 
indicator to the table.  Place the gauge over the extreme 
right side of the table roll and find the high point of the 
roll arc.   
 
3. 
The standard setting is .008" (.2mm); if the reading 
is greater or less than this reading, reach below the table 
and loosen the hex nut (C) which is above the cam (D) 
Rotate the hex screw (E) to position the .008" setting.  