Southbend SB1013 Manual De Usuario

Descargar
Página de 80
For Machines Mfg. Since 7/09
EVS Toolroom Lathes
-13-
P R E P A R A T I O N
6.
  Attach the lifting straps to forklift forks or a 
hook and chain, as shown in Figures 8–9.
Forklift
Forks 
Lifting 
Straps
12" Long
2x6 Board
12" Long
2x6 Board
Figure 8. Lathe set up for lifting with forklift.
7.
 
Unbolt the lathe from the shipping pallet, 
then with an assistant to help keep the lathe 
from swaying, raise the lathe a couple of 
inches.
— If the load is not well balanced, or you 
see any other difficulties with the lifting 
equipment, immediately lower the lathe 
to the pallet again. Resolve any lifting or 
balancing issues, then repeat this step.
8.
  With assistance to steady the load, move it to 
the prepared location and lower it in place.
Lifting Hook 
with Chain
Lifting 
Straps
12" Long
2x6 Board
12" Long
2x6 Board
Figure 9. Lathe set up for lifting with hook and chain.
Leveling & Mounting
You must level your machine and either use the 
included foot pads and leveling hardware or bolt 
your lathe to the floor. Because mounting your 
lathe to the floor with permanent hardware is an 
optional step and floor materials may vary, floor 
mounting hardware is not included.
Leveling
Leveling machinery helps precision components, 
such as bedways, remain straight and flat during 
the lifespan of the machine. Components on an 
unleveled machine may slowly twist due to the 
dynamic loads placed on the machine during 
operation.
For best results, use a precision level that 
is at least 12" long and sensitive enough to 
show a distinct movement when a 0.003" shim 
(approximately the thickness of one sheet of 
standard newspaper) is placed under one end of 
the level.
See the figure below for an example of a high 
precision level.
For accurate turning results and to prevent 
warping the cast iron bed and ways, the lathe 
bedways MUST be leveled from side-to-side 
and from front-to-back.
Re-check the bedways 24 hours after 
installation, two weeks after that, and then 
annually to make sure they remain level.
Figure 10. Example of a precision level.