Southbend SB1012 Manual De Usuario

Descargar
Página de 144
-22-
For Machines Mfg. Since 7/09
EVS Toolroom Lathes
P R E P A R A T I O N
7.
 
After completing the previous step, stop the 
spindle and move the gearbox range lever to 
neutral, then move the spindle speed range 
lever to high.
8.
  Turn the lathe ON and let it run for ten 
minutes in each speed of 400, 1000, and 2500 
RPM.
9.
 After 
completing 
Step 8, reduce the spindle 
speed to 400 RPM and let the lathe run for a 
final 15 minutes as a cool-down.
10.
  Turn the lathe OFF.
11.
  Change the oil in all of the reservoirs, 
tighten the V-belts, and perform all 
other lubrication steps mentioned in the 
Maintenance section of this manual.
For your convenience, the adjustments listed 
below have been performed at the factory.
However, because of the many variables involved 
with shipping, we recommend that you at least 
verify the following adjustments to ensure the 
best possible results from your new machine.
Step-by-step instructions for these adjustments 
can be found on the pages referenced below.
Factory adjustments that should be verified:
s
4AILSTOCK
s
#OMPOUND
s
'IB
Recommended 
Adjustments
After the first 16 hours of use, the V-belts will 
stretch and seat into the pulley grooves. The 
V-belts must be properly re-tensioned after 
this period to avoid reducing their useful life. 
Refer to the V-Belts section on Page 69 for 
detailed instructions.
5.
  Disengage the half nut and the feed control 
levers shown in Figures 30–31.
Figure 30. Power fed and half nut levers disengaged.
Half Nut Lever 
Disengaged (Up)
Feed Control Lever Disengaged 
(Neutral Position)
6.
  Turn the lathe ON, and let it run for ten 
minutes in each speed of 20, 200, and 400 
RPM, using the spindle speed dial (Figure 
32
) to adjust the speed.
Figure 32. Spindle speed controls.
Low
20-400 RPM
High
400-2500 RPM
Spindle Speed Dial
Figure 31. Feed control lever and half nut in 
disengaged positions.
Engaged
HALF NUT
LEVER
Disengaged
Cross Slide
Neutral
FEED CONTROL
LEVER
Carriage