Anton/Bauer 90 Manual De Usuario

Descargar
Página de 20
 
 
 12  
4. 
Low voltage batteries can also be caused by allowing batteries to 
remain off the charger for extended periods causing the LCD display 
to be blank, indicating that the electronic circuitry has removed all 
load from the battery cells – including the display. In the case that the 
battery is in a low voltage condition the battery should be returned to 
the charger. The charge routine will not be initiated by the charger 
until all other batteries have completed their fast charge routines.  
Therefore, a low voltage battery can be installed on an InterActive 
charger without the charger indicating recognition.  The battery should 
remain on the charger until charging is complete. It may be helpful to 
remove other batteries before placing a battery with a blank display on 
the charger.
 
 
5. 
Never leave any battery unattended on equipment.
 
 
6. 
Routine use of a battery at discharge rates greater than the battery 
rating (e.g. 90 watts maximum, <50 watts for lighting load) can reduce 
overall service life.  Always select the proper size battery for your 
application.
 
 
7. 
Discharging the battery for diagnostic purposes should only be 
performed on an occasional basis  (once every 6-8 weeks at most).  
Unnecessary discharging only detracts from overall life.
 
 
8. 
Periodic cleaning of both the charger terminals and battery terminals 
will ensure continued reliable operation. Clean the terminals 
occasionally with a pencil eraser or lightly scrape the surface with a 
blunt instrument to help reduce this possibility.
 
 
Anton/Bauer publishes a comprehensive “Video Battery Handbook” to 
help you further understand the care and use of video batteries.  This guide 
is available at no charge by contacting Anton/Bauer at 1-800-422-3473 or 
203-929-1100 or fax 203-929-9935. It can also be downloaded from the 
web at www.antonbauer.com.