 15  
DIONIC 90 BATTERY SPECIFICATIONS 
OUTPUT VOLTAGE 
14.4v Nominal 
12.4 ~ 16.8v 
Operating 
CAPACITY 
(CELL CAPACITY) 
90 WH Nominal 
(6.3 AH Rated) 
FUSE 
Internal  8amp 
RECOMMENDED OPERATION
15 - 50 watts
(MAXIMUM DISCHARGE RATE) 
(90 watts)
TYPICAL RUN-TIME 
@ 20w - 4 ½  hrs.
@ 25w - 3 ½  hrs. 
@ 40w - 2 ¼ hrs. 
WEIGHT 
1.7 lbs 
SIZE 
1/4
 x 3 
1/2
 x 2 
1/8
 
CHARGE TEMPERATURE 
0 – 40°C 
DISCHARGE TEMPERATURE
-20 – 60°C 
STORAGE TEMPERATURE 
-20 – 50°C 
 
1
 DIONIC 90 may be used to power both camera and on camera light 
however its maximum cold halogen lighting load is restricted to 50 watts.  
 
Routine use of a battery at discharge rates greater than the recommended 
operating range can reduce overall service life. Always select the proper 
size battery for your application.