Philips T5VHO Manual De Usuario

Descargar
Página de 14
LAMP
LAMP
BALLAST
RED
BLUE
YELLOW
BLACK
WHITE
RED
BLUE
YELLOW
YELLOW
BLUE
BROWN
RED
BLUE/WHITE
ORANGE
GREY/RED
(Hot)
250V,
1mA
Neutral or (any Hot)
BLACK WITH ORANGE STRIPES
BLACK WITH WHITE STRIPES
S
(Neutral)
LAMP
LAMP
LAMP
LAMP
LAMP
LAMP
BALLAST
RED
BLUE
YELLOW
RED
BLUE
YELLOW
BLACK WITH ORANGE STRIPES
BLACK WITH WHITE STRIPES
(Hot)
(Neutral)
Advance HCN4S5490C2LSG T5 VHO Ballast
Advance ICN2S5490CWL T5 VHO Ballast
Four-lamp operation
Two-lamp operation
Advance HCN2S5490CWL T5 VHO Ballast
Two-lamp operation
OEM Design Guide
Philips T5 VHO and HO Extreme Temperature Lamps and Ballasts
13
Notes:
• Max.Voltage RED-YELLOW
Leads 340Vrms.
• Insulate unused leads for 600V.
• Ballast case must be grounded.
• Mount lamps within
1
4
" of grounded
metal reflector.
Notes:
• Ballast case must be grounded.
• Mount lamps within
1
4
" of grounded
metal reflector.
• Install in accordance with National and
Local Electrical Codes.
• Use 18AWG Solid Copper Wire
Rated >=600V. Strip Wire
3
8
".