Philips P-5811 Prospecto

Descargar
Página de 2
Rated
Product
Pkg
Average
Symbol/
Number
Description
Watts
Volts
Qty
Bulb
Base
Life (hrs)
1
Footnote
Availability
20178-0
25A/IF/TG 130V 24/2
25
130
24/2
A-19
Medium
2500
10
Made to Order
20179-8
25T10/TG 120/130V 24/1
25
120
24
T-10
Medium
1000
10
Made to Order
20181-4
30R20/TG 120V 12/1
30
120
12
R-20
Medium
2000
6, 10
Made to Order
20182-2
40A15/TG 120/130V 120/1
40
120
120
A-15
Medium
1000
10
Made to Order
20183-0
40A/CL/TG 120/130V 48/1
40
120
48
A-19
Medium
1500
10
Made to Order
20184-8
40T10/TG 120/130V 24/1
40
120
24
T-10
Medium
1000
10
Made to Order
20185-5
50A/RS/TG 120/130V 120/1
50
120
120
A-19
Medium
1000
10
Made to Order
20187-1
50R20/TG 120V 12/1
50
120
12
R-20
Medium
2000
6, 10
Made to Order
20188-9
60A19/35/TG 120V 48/1
60
120
48
A-19
Medium
3500
Made to Order
15925-1
60A/35/TG 130V 48/1
60
120
48
A-19
Medium
3500
Stocked
20471-9
60F15/CL/TG
60
120
24
F-15
Medium
1500
10
Made to Order
20190-5
65BR30/FL55/TG 120V 12/1
65
120
12
BR-30
Medium
2000
6, 10
Made to Order
20191-3
65BR30/FL55/TG 130V 12/1
65
130
12
BR-30
Medium
2000
6, 10
Made to Order
20192-1
75A/RS/VS 120/130V12/1
75
120
12
A-19
Medium
1000
10
Made to Order
20195-4
75A/TG 120V 48/1
75
120
48
A-19
Medium
750
10
Made to Order
15933-5
75A/TG 130V 48/1
75
120
48
A-19
Medium
750
10
Stocked
20018-8
75A/RH/TG 120/130V 12/1
75
120
12
A-21
Medium
1000
10
Stocked
15934-3
100A/TG 130V 48/1
100
130
48
A-19
Medium
750
10
Stocked
15927-7
100A/RS/VS/BR/TG 120/130V 60/1
100
120
60
A-21
Medium
1000
Stocked
15923-6
100PAR/1/CL/TG 130V 12/1
100
130
12
BR-38
Medium
2000
2, 3, 4
Stocked
20196-2
100A/CL/RS/VS/TG 120/130V 60/1
100
120
60
A-21
Medium
1000
10
Made to Order
20197-0
100A21/TG 120/130V 120/1
100
120
120
A-21
Medium
750
10
Made to Order
20198-8
100A21/99/TG 120/130V 60/1
100
120
60
A-21
Medium
2500
10
Made to Order
20199-6
120BR/FL60/TG 130V 24/1
120
130
24
BR-40
Medium
2000
6, 10
Made to Order
20200-2
120BR/FL60/TG 120V 24/1
120
120
24
BR-40
Medium
2000
6, 10
Made to Order
15930-1
125BR40/1/TG 120V 4/1
125
120
4
BR-40
Medium
5000
5, 6, 7
Stocked
15931-9
150A/35/RS/BR/TG 120/130V 60/1
150
120
60
A-21
Medium
3500
Stocked
20203-6
150BR38/FL/TG 130V 6/1
150
130
6
BR-38
Medium
2000
2, 3, 4
Made to Order
20204-4
200A/99/TG A23 120/130 60/1
200
120
60
A-23
Medium
2500
10
Made to Order
20472-7
200PS30/RS/IF/TG
200
120–130
60
PS-30
Medium
1000
10
Made to Order
15932-7
250R40/HR/TG 120V 4/1
250
120
4
R-40
Medium
5000
5, 6, 7
Stocked
20205-1
250BR40/1/TG 120V 4/1
250
120
4
BR-40
Medium
5000
5, 6
Made to Order
20206-9
300M/99IF PS25 120V 60/1
300
120
60
PS-25
Medium
2500
10
Made to Order
20207-7
300M/PS30/IF/TG 120/130V 60/1
300
120
60
PS-30
Medium
750
10
Made to Order
20474-3
300/IF/TG
300
120–130
12
PS-35
Mogul
1000
10
Made to Order
Philips TuffGuard
Incandescent Coated Lamps
Electrical,Technical and Ordering Data
(Subject to change without notice)
Philips Lighting Company
200 Franklin Square Drive
P.O. Box 6800
Somerset, NJ 08875-6800
1-800-555-0050
A Division of Philips Electronics North America Corporation
Printed in USA 1/07
P-5811
Philips Lighting
281 Hillmount Road
Markham, Ontario
Canada L6C 2S3
1-800-555-0050
A Division of Philips Electronics Ltd.
www.philips.com
1. Rated average life is the length of operation (in hours) at which point an average of 50% of the lamps will still be operational and 50% will not.
INSTRUCTIONS AND WARNINGS:
• Should not be used in equipment where the base temperature will exceed 500°F.
• Light output is maintained best when operated within 45° of vertically base up.
• The bulb, though made of heat resistant glass, may break if moisture falls on it. Not recommended for use in enclosed, close fitting housings.
• Average laboratory life in excess of 5000 hours. In-service life depends upon service conditions.
• Do not allow hot bulb to come in contact with liquid or metal parts of the fixture as glass may shatter. Do not use outdoors. Do not operate
in close proximity to flammable materials or those adversely affected by heat or drying. Operate only in heat resistant sockets.
• CAUTION: Do not operate in close proximity to flammable materials or those adversely affected by heat or drying.
Operate only in heat resistant sockets.
WARNING: Use carefully. May cause serious burns. Do not use over insensitive skin areas or in the presence of poor circulation.
The unattended use of infrared heat by children or incapacitated persons may be dangerous.
—Lamp should not be placed closer than 18" to the surface being irradiated.
—Do not use for therapeutic or topical applications unless recommended by a physician.
—For food warming, use only lamps with heat resisting glass.
• Design volts 115.
• Operate only in porcelain sockets.
• Aluminum base.
WARNINGS:
• Coating can withstand bulb-wall temperatures of up to 500°F
• Lamps should not be used in enclosed fixtures or fixtures that do not allow heat dissipation.
• Lamps must be installed and operating in ambient temperature below 150°F
• Under extreme conditions glass fragments may escape the coating
Made to order requires 3 week lead time
(No product returns on made to order lamps)