Philips SKSGPK228 Prospecto

Descargar
Página de 2
For Factory Technical Information: (978) 657-7600 • Fax (978) 658-0595
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
www.lightolier.com © 2009 a Philips Group
Section 5/Folio MA12-16
Job Information  
Type:
Lightolier is a Philips group brand
Skyway 
SKS2GPK228 or 254
Page 2 of 2
2' x 4' Recessed Fluorescent, Tri-Lens Frame
Static or Air Supply/Return, 2 or 3 Lamp T 5 or T5HO
Ordering Information
Explanation of Catalog Number. Example: SKS2GPK254UNVPG
Options/Accessories
Fusing: Internal fast blow fusing: SUFFIX: A.
Internal slow blow fusing: SUFFIX: C.
Drywall Kit: Order Catalog Number: FK92X4.
Electrical Wiring Options: Consult factory.
For motion or light sensor: See Folio OA20-10 and OA20-30.
Specifications
Performance: In an installation of 2 lamp 28W luminaires in a room cavity
ratio of 1, with reflectance 80% ceiling, 50% wall, 20% floor, the C.U. shall not
be less than .78. To reduce glare the average brightness at 65° shall not exceed
1109 candelas per square meter. To control veiling reflections, luminaire output
in the 30°-90° zone shall not be less than 64.1%. 
Air Handling: (SKA only) side air passages for air supply or air return. Supply
air is discharged vertically. Optional side closure strips. Air return is also provid-
ed through the lamp compartment through fixture body ends.
MaterialsChassis parts are die-formed code gauge cold rolled steel. Housing has
side rails hemmed over and housing ends turned-in for safe handling.
FinishChassis exterior–black baked polyester enamel. Cavity–white baked
polyester enamel minimum 86% reflectance. Rust preventative undercoating.
Reflectors- 95% reflective white powder coated. 
Specifications (continuned)
Lens: Proprietary high quailty frost white acrylic and clear conical prism lens assembly.
Electrical: Thermally protected class “P’ ballast C.B.M. approved, non PCB. If K.O. is within 3" of
ballast, use wire suitable for at least 90°.
UL Listed for damp locations.
Labels: I.B.E.W./UL and ULc Listed.
This product may have a mercury containing lamp. Manage in accord with Disposal Laws. 
See: www.lamprecycle.org
Options:
Add appropriate
suffix to catalog
no., ie: (A)
Skyway
Recessed
Fluorescent
Body Style:
= Static
= Air
2
Fixture
Width
Ceiling Type:
= Standard
Grid
= Slot Grid
P
Side Lens:
P= Frost White
Acrylic Lens
K
Center Lens:
K
= Pattern 19
.156 Virgin
Acyrlic Lens
Lamp
Quantity
2=2 Lamp
3=3 Lamps
0.0
45.0
90.0
FLUX
0
1814
1814
1814
5
1789
1784
1784
169
15
1690
1687
1716
479
25
1521
1542
1608
715
35
1271
1316
1341
810
45
859
867
853
673
55
505
559
511
486
65
282
298
280
299
75
143
128
112
140
85
13
10
6
24
90
10
9
5
Model No. SKS2GPK228120WA 
LER = FP - 64.1      IW - 54.5      BF - 0.92
Comparative yearly lighting energy cost per
1000 lumens = $3.74
Report Number: G2008274
Catalog Number: SKS2GPK228120WA
Lamps: (2) F28T5/835/ALTO
Luminaire: Skyway Recessed 2' x 4' fixture
prismatic acrylic lens assembly.
Ballast: ST232120E
Report is based on 2600 Lumens per lamp.
Efficiency: 73.0%
CIE Type-Direct-Indirect
Plane:
0-Deg
90-Deg
Spacing Criteria:
1.2
1.2
Shielding Angles:
90
90
Plane:
0-Deg
90-Deg
Luminous Length:
45.600
21.600
CANDELA DISTRIBUTION
AVERAGE AVERAGE AVERAGE AVERAGE
IN DEG.
0-DEG.
45-DEG.
90-DEG.
45
1911.
1929.
1898.
55
1385.
1533.
1401.
65
1050.
1109.
1042.
75
869.
778.
681.
85
235.
180.
108.
LUMINANCE DATA IN CANDELA/SQ. METER
COEFFICIENTS OF UTILIZATION –
ZONAL CAVITY METHOD. EFFECTIVE 
FLOOR CAVITY REFLECTANCE 0.20
0
RC
80
50
30
RW 70 50 30 50 30 10 50 30 10
0
1 81 78 75 73 70 69 70 69 67
0
2 74 69 65 65 62 59 63 60 58
0
3 68 62 56 58 54 51 57 53 50
0
4 63 55 50 53 48 44 51 47 44
0
5 59 50 44 48 43 39 46 42 39
0
6 54 46 40 44 39 35 42 38 35
0
7 51 42 36 40 35 31 39 34 31
0
8 47 38 32 37 32 28 36 31 28
0
9 44 35 30 34 29 26 33 29 26
10 42 33 27 32 27 23 31 26 23
ZONE
LUMENS % LAMP
% FIXT
0
0-
0
30
1363
26.2
35.9
0
0-
0
40
2173
41.8
57.3
0
0-
0
60
3333
64.1
87.8
0
0-
0
90
3796
73.0
100.0
90-180
000
0
0.0
00
0.0
0
0-180
3796
73.0
100.0
ZONAL LUMEN SUMMARY
Voltage:
120, 277 or
UNV=120-277
0.0
45.0
90.0
FLUX
0
2812
2812
2812
5
2790
2790
2790
265
15
2668
2666
2690
755
25
2446
2470
2551
1145
35
2107
2174
2281
1356
45
1576
1541
1527
1200
55
938
1009
935
880
65
524
581
525
568
75
291
263
252
299
85
86
63
58
77
90
13
12
7
Model No. SKS2GPK254UNVPG
LER = FP - 56.9      IW - 114.9      BF - 1.0
Comparative yearly lighting energy cost per
1000 lumens = $4.21
Report Number: G2008317
Catalog Number: SKS2GPK254UNVPG
Lamps: (2) F54T5/835/HO/ALTO
Luminaire: Skyway Recessed 2' x 4' fixture
prismatic acrylic lens assembly.
Ballast: ICN-2S25-90C
Report is based on 4500 Lumens per lamp.
Efficiency: 72.7%
CIE Type-Direct-Indirect
Plane:
0-Deg
90-Deg
Spacing Criteria:
1.2
1.3
Shielding Angles:
90
90
Plane:
0-Deg
90-Deg
Luminous Length:
45.600
21.600
CANDELA DISTRIBUTION
AVERAGE AVERAGE AVERAGE AVERAGE
IN DEG.
0-DEG.
45-DEG.
90-DEG.
45
3506.
3428.
3397.
55
2573.
2767.
2564.
65
1950.
2163.
1954.
75
1769.
1599.
1532.
85
1552.
1137.
1047.
LUMINANCE DATA IN CANDELA/SQ. METER
COEFFICIENTS OF UTILIZATION –
ZONAL CAVITY METHOD. EFFECTIVE 
FLOOR CAVITY REFLECTANCE 0.20
0
RC
80
50
30
RW 70 50 30 50 30 10 50 30 10
0
1 80 77 74 72 70 68 69 68 66
0
2 73 68 62 64 61 58 62 59 56
0
3 67 60 55 57 53 49 55 52 48
0
4 62 54 48 51 47 43 50 46 42
0
5 57 49 43 46 41 38 45 41 37
0
6 53 44 38 42 37 33 41 36 33
0
7 50 40 34 39 33 30 38 33 29
0
8 46 37 31 35 30 27 35 30 27
0
9 43 34 28 33 28 24 32 27 24
10 41 31 26 30 25 22 30 25 22
ZONE
LUMENS % LAMP
% FIXT
0
0-
0
30
2165
24.1
33.1
0
0-
0
40
3521
39.1
53.8
0
0-
0
60
5601
62.2
85.6
0
0-
0
90
6545
72.7
100.0
90-180
000
0
0.0
00
0.0
0
0-180
6545
72.7
100.0
ZONAL LUMEN SUMMARY
SK
Standard Skyway
SY
For NYC Code – I.B.E.W. Manufactured
NK
For NYC Code – Local 3 Manufactured
Lamp:
(By Others)
28=T5 28W
54=T5HO 54W
(Nominal 48")
Ballast Type:
<
20THD
<
10THD
1 or 2 Lamp 28W Elec. T5
P
1 or 2 Lamp 28W Elec. T5
PG  ††
1 or 2 Lamp 54W Elec. T5HO 
PG  ††
1-3 Lamp 54W Elec. T5HO
PU  ††
†Instant Start (120, 277 or UNV)
††Program Rapid Start (UNV only)