Philips E3 Series Prospecto
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
www.lightolier.com © 2008 Philips Group • E0308
We reserve the right to change details of design, materials and finish.
www.lightolier.com © 2008 Philips Group • E0308
Job Information
Type:
Job Name:
Cat. No.:
Lamp(s):
Notes:
E3 Series Emergency Lighting
E3
Page 1 of 2
6 or 12 Volt 14 to 50 Watts Thermoplastic Housing
Lightolier is a Philips group brand
The E3 Series provides egress lighting in a wide variety of wattages. The thermoplastic housing and high performance electronics make the units ideal for commer-
5.0”
(12.7 cm)
13.0”
(33.0 cm)
Side
View
Front View
4.5”
(11.4 cm)
6.5”
(16.5 cm)
Features
1. Illumination: Allows up to three mounted lamp heads. The standard lamp
head incorporates a high performance parabolic reflector with a wedge base
tungsten lamp. Allows maximum spacing between units along a path of
egress.
tungsten lamp. Allows maximum spacing between units along a path of
egress.
2. Housing: Constructed of impact resistant, UL 94 V-0, 5VA white thermo-
plastic. Universal J-box mounting pattern, key hole slots or shelf mounting.
3. Electronics: 120/277 VAC dual voltage input with surge-protected, solid-
state circuitry. Charging system is complete with low voltage disconnect, AC
lockout, brownout protection, AC indicator lamp and test switch.
lockout, brownout protection, AC indicator lamp and test switch.
4. Battery: Maintenance free, sealed lead calcium battery has an estimated
service life of 5 years, and an operating temperature range of 65°F (19°C) to
85°F (30°C). Maintenance free, sealed nickel cadmium battery has an esti-
mated service life of 10 years, and an operating temperature range of 20°F
(-7°C) to 95°F (35°C).
85°F (30°C). Maintenance free, sealed nickel cadmium battery has an esti-
mated service life of 10 years, and an operating temperature range of 20°F
(-7°C) to 95°F (35°C).
5. Input Power Requirements:
120 VAC - 0.18 amps (20 watts);
0.08 amps (20 watts)
Code Compliance
UL 924 listed, CUL listing for 30 minute operation.
Options
SD = Self-Diagnostics
SA = Self-Diagnostics with Alarm
SDTD = Self-Diagnostics with Time Delay
V = Voltmeter
SA = Self-Diagnostics with Alarm
SDTD = Self-Diagnostics with Time Delay
V = Voltmeter
(not available with Ammeter (A) option)
1
A = Ammeter
(not available with Voltmeter (V) option)
1
T1 = 120 VAC Time Delay
(15 minutes)
T2 = 277 VAC Time Delay
(15 minutes)
LCK1 = Line Cord
(6’, 120 VAC field installed)
DL = UL Damp Location Listing
2
Options (continued)
F1 = 120 VAC Fuse
F2 = 277 VAC Fuse
P1 = 120 VAC Power Switch
P2 = 277 VAC Power Switch
DC = DC Power Switch
ST = Special Input Transformer
F2 = 277 VAC Fuse
P1 = 120 VAC Power Switch
P2 = 277 VAC Power Switch
DC = DC Power Switch
ST = Special Input Transformer
(specify voltage and frequency)
HI = Lamp Heads Installed at Factory
Multiple option configurations may void UL listing. Consult factory for specifics.
Accessories
WG5 = Wire Guard
PCS1 = Polycarbonate Vandal Shield
MSSHELFW = White Mounting Shelf
PCS1 = Polycarbonate Vandal Shield
MSSHELFW = White Mounting Shelf
How to Specify:
E3
W
SERIES
BATTERY
BATTERY/
# OF
LAMP
HOUSING
DC WATTAGE
HEADS
HEADS
COLOR
W = White
6V
S6 = 5.4W
S7 = 7.2W
S9 = 9W
12V
S9 = 9W
S12 = 12.5W
S18 = 18W
1 = One
2 = Two
3 = Three
Blank = No Heads
6V, Lead Cadmium
18L = 18W
2
25L = 25W
2
36L = 36W
2
50L = 50W
2
6V, Nickel Cadmium
14N = 14W
18N = 18W
25N = 25W
50N = 50W
12V, Lead Calcium
36L = 36W
2
50L = 50W
2
12V, Nickel Cadmium
25N = 25W
50N = 50W
1 = 6V
2 = 12V
E3 = Thermoplastic
Emergency Lighting
Unit
Complete Fixture consists of unit and two lamp heads. Select options and accessories below. For additional lamp heads, see RH Specification Sheet.
NOTES:
1) Not available for use with SD, SA and SDTD options.
2) Selected models are available with damp location option.
2) Selected models are available with damp location option.