Philips P-2055-D Prospecto

Descargar
Página de 2
Philips White SON
®
Lamps
© 2007 Philips Lighting Company. All rights reserved.
Printed in USA 06/07
P-2055-D
www. philips.com
Philips Lighting Company
200 Franklin Square Drive
P.O. Box 6800
Somerset, NJ 08875-6800
1-800-555-0050
A Division of Philips Electronics North America Corporation
Philips Lighting
281 Hillmount Road
Markham, Ontario
Canada L6C 2S3
1-800-555-0050
A Division of Philips Electronics Ltd.
Above specifications subject to change without notice.
Printed on chlorine free paper from Sappi Fine Paper mills, who are accredited with EMAS environmental certification.
Sappi claims that the pulp used in the manufacture of Magno Dull paper is derived from environmentally certified forests.
Electrical and Technical Data
Lamp Current Crest Factor (Maximum) ————1.8
Warm-up to 80% Full Brightness ———3–4 minutes
Restrike Time for Hot Lamps ———— 1–2 minutes
Starter Pulse Voltage—Peak ——————3500-4900
Pulse Width @ 90% Peak
—0.5 Micro Sec. Minimum
Pulse per Cycle (Minimum) ——————————1
Physical Characteristics
Bulb ——————————————ED-17 (SDW)
————————————————T-10 (SDW-T)
Bulb Finish ———————————Diffuse (SDW)
——————————————— Clear (SDW-T)
Base —————————————Medium (SDW)
———————————————PG-12 (SDW-T)
Max. Overall Length (MOL) —5.438'' (xxmm) (SDW)
———————————5.875" (XXmm) (SDW-T)
Light Center Length (LCL) —3.438'' (xxmm) (SDW)
———————————3.563" (XXmm) (SDW-T)
Arc Length —————————0.X'' (7mm) (50W)
———————————— 0.XX" (9mm) (100W)
Max. Bulb Temp. ————350ºC (XXXºF) (50W T-10)
————— 400˚C (XXX˚F) (50W & 100W ED-17)
————————— 450˚C (XXX˚F) (100W T-10)
Max. Base Temp. ———————150° C (50W T-10)
—————————190° C (50W & 100W ED-17)
————————————— 180° C (100W T-10)
Standard Package Quantity ————————— 12
Operating Characteristics
Rated Average Life, Hours.
3,4
———————10,000
Color Rendering Index (CRI)—————————85
Color Temperature ———————————2700K
Operating Position
Universal
Ordering Data
Lamp
Oper.
Approx.
Approx
Product
Lamp
Lamp
Current
ANSI
Initial
Mean
Number
Ordering Code
Watts
Volts
(Amps)
Code
Lumens
1
Lumens
2
31344-5
SDW-50W/LV/D
50
45
1.4
S104
2350
2000
31346-0
SDW-100W/LV/D
100
52
2.5
S105
4900
4170
30229-9
SDW-T50W/LV
50
45
1.4
S104AF-50
2300
2070
30228-1
SDW-T100W/LV
100
52
2.5
S105NZ-100
5000
4250
WHITE SON
®
RECOMMENDED WARNINGS, CAUTIONS AND
OPERATING INSTRUCTIONS
R
“WARNING: These lamps must be operated in fixtures
designed for use with High Pressure Sodium lamps.The
fixture wattage rating must match the wattage indicated on the
outer glass bulb. Do not scratch the outer bulb or subject it to
pressure as this could cause the outer bulb to crack or shatter.
A partial vacuum in the outer bulb may cause glass to fly if the
glass is struck. Operating the lamp improperly may result in
PERSONAL INJURY, PROPERTY DAMAGE, BURNS AND FIRE.
1. If the outer glass bulb is broken, shut off power immediately
and remove the lamp after it has cooled.
2. Use only auxiliary equipment meeting Philips and/or ANSI
standards. Use within voltage limits recommended by
ballast manufacturer.
A. Operate lamp only within specified limits of operation.
B. For total supply load refer to ballast manufacturers
electrical data.
3. Protect lamp base, socket and wiring against moisture,
corrosive atmospheres and excessive heat.
4. Replace the lamp if the outer glass bulb has been scratched,
cracked or damaged in any way.
5. If a lamp bulb support is used, be sure to insulate the support
electrically so as to avoid possible decomposition of the
bulb glass.
6. Do not use this lamp in a fixture which redirects a substantial
portion of the energy toward the arc tube and its immediate
vicinity, as this may lead to very early lamp failure.
7. Take care in handling and disposing of lamps. If arc tube is broken,
avoid skin contact with any of the contents or fragments.
8. The arc tube of this lamp contains sodium and mercury.
Dispose of lamp in accordance with federal, state and
local requirements.
C.I.E. Color Coordinates
X
Y
50 Watt
.462
.414
100 Watt
.461
.410
Maximum Color Shift:
-250K (7500 hours)
1) Based on photometry of 100-hour lamps in vertical position at rated watts. Lumen output rating applies to all operating positions.
2) Lumen output at 50% rated life.
3) Based on survival of at least 50% of the lamps, operated under specified test.