Agilent Technologies 8164A Manual De Usuario

Descargar
Página de 274
Measurement Operations & Settings
Signal Conditioning
148
Agilent 8163A/B, 8164A/B & 8166A/B Mainframes, Fifth Edition
Signal Conditioning
The commands in this section allow you to control Agilent 8156x, and 
8157x Attenuator modules
The INPut and OUTput commands
command:
:INPut[n][:CHANnel[m]]:ATTenuation
syntax:
:INPut[n][:CHANnel[m]]:ATTenuation<wsp><value>[dB] | MIN | DEF | MAX
description:
Sets the attenuation factor (
α) for the instrument. The attenuation factor is used, together 
with an offset  factor (
α
 Offset 
) to set the filter attenuation ( 
α
 
filter 
).
α 
(new)
  (dB) = 
α
 
filter (new)
  (dB) + 
α
 Offset
  (dB)
Set the attenuation factor by sending a value (the default units are dB), or by sending MIN, 
DEF, or MAX.
parameters:
<value>[dB]
MIN | DEF
MAX
The attenuation in dB. 
The values where 
α
 
filter 
  = 0dB
The value where 
α
 
filter 
  is at its greatest.
response:
none
example:
INP1:ATT 14dB
affects:
All attenuator modules
command:
:INPut[n][:CHANnel[m]]:ATTenuation?
syntax:
:INPut[n][:CHANnel[m]]:ATTenuation?<wsp> MIN  |  DEF  |  MAX
description:
Returns the current attenuation factor (
α), in dB.
α
   (dB) =  
α
 
filter
  (dB) + 
α
 Offset
  (dB)
parameters:
MIN | DEF | MAX Returns the minimum, default, or maximum value of the attenuation fac-
tor possible.
response:
4 byte Intel floating point; attenuation in dB. 
example:
INP1:ATT? 
 14<END>
affects:
All attenuator modules