The Status Model 
Status Registers
Each node of the status circuitry has three registers:
• A condition register (CONDition), which contains the current status. 
This register is updated continuously. It is not changed by having its 
contents read.
• The event register (EVENt), which contains details of any positive 
transitions in the corresponding condition register, that is, when a bit 
changes from 0 
→ 1. The contents of this register are cleared when it is 
read. The contents of any higher-level registers are affected with regard 
to the appropriate bit.
• The enable register (ENABle), which enables changes in the event 
register to affect the next stage of registers.
The structures of the Operational and Questionable Status Systems are 
similar.  Figure 4  describe how the Questionable Status Bit (QSB) and the 
Operational Status Bit (OSB) of the Status Byte Register are determined.
Figure 3 The Registers and Filters for a Node
The event register is the only kind of register that can affect the next stage 
of registers.
N O T E
Enable Registers
To the
Condition Register
of the Next Node
Event Registers
Condition Registers
OR
1 1 1 1 1
A positive transition in the condition 
causes the corresponding bit of the 
to change from 0 
→ 1. 
corresponding event register
register, when a bit changes from 0 