Testing Procedures 
 
!
WARNING
 
To avoid risk of electrical shock, personal injury or death; disconnect power to oven before servicing, unless  
testing requires power. 
20 
16023416 
©2004 Maytag Services 
 
 
“Quick Test” Mode for Electronic Range Control 
Follow the procedure below to perform the Electronic Range Control (ERC) quick test.  Instructions must be entered 
within 32 seconds of each other (via the touch pad) or the ERC will exit the quick test. 
1.  Press and hold the 
UPPER CANCEL and BROIL pads for 3 seconds. 
2.  Once the control has entered the “Quick Test” mode, release both pads. 
3.  Press each of the following pads indicated in the table below. 
NOTE: 
Press the applicable pad once to activate the associated response. 
Press the applicable pad a second time to deactivate the associated response. 
Display will indicate the following: 
Pad Response 
 
BAKE ................................... Bake DLB and Bake relay activated 
BROIL.................................. Broil DLB and Broil relay activated 
KEEP WARM ...................... Bake DLB and Broil DLB activated 
CONVECT BAKE ................ Convection Fan on low speed 
CONVECT ROAST ............. Convection Fan on high speed 
CLEAN................................. MDL relay activated 
COOK & HOLD.................... Displays last diagnostic code 
FAVORITE........................... Displays EEPROM version number 
TIMER ................................. Displays main code version number 
CLOCK ................................ All display segments illuminated 
OVEN LIGHT....................... Oven light activated 
CANCEL .............................. Exit Quick Test mode 
1........................................... Even segments on 
2........................................... Odd segments on 
3........................................... Convection Ring activated; Convection Ring DLB activated 
4........................................... N/A 
5........................................... N/A 
6........................................... N/A 
7........................................... N/A 
8........................................... N/A 
9........................................... N/A 
AUTOSET............................ Steps through last 5 diagnostic codes 
Setup Options (0) pad is pressed “Press Desired Pad for Selection” will scroll in the display. When a feature is 
displayed the 
AUTO SET pad is used to toggle the options. Use the chart below to identify the available options. 
Control 
Function 
Pad 
Selection 
Default Option 
Additional Options 
12 hour shut-off 
12 HR Energy Saver ON 
12 HR Energy Saver OFF 
Timer beeps 
Timer Reminder Beeps for 5 Min. 
Timer Reminder Beeps for 30 Min. 
No Timer Reminder Beeps 
Cook time beeps 
Cook Time Reminder Beeps for 30 Min. 
Cook Time Reminder Beeps for 5 Min.
No Cook Time Reminder Beeps 
Control lock 
Control Unlocked 
Control Locked 
Scroll speed 
Medium Speed 
Fast Speed Slow Speed 
Volume level 
6 bars 
1 to 8 bars 
Temp C/F 
Degrees F 
Degrees C 
Language 8 
English 
French, 
Spanish 
Default 
Press AUTO SET for Factory Settings 
N/A 
Display On/Off 
Clock 
Clock Display is ON 
Clock Display is OFF