Moyer Diebel MH-60M5 Manual De Usuario

Descargar
Página de 76
INSTALLATION
7
Figure 5
Hot Water Connection
(MH-60 Only) 
3/4" NPT
Figure 8
Hot Water Connection
(MH-6N, MH-6L Only)
3/4" NPT
INSTALLATION (Cont.)
Plumbing Connections
NOTE:
Plumbing connections must comply 
with all applicable sanitary and 
plumbing codes.
Water Connections
1. All MH series dishwashers require 
a single, hot water supply. 
The hot water connection to all MH 
series dishwashers is 3/4" NPT. 
The connection is made from 
underneath the dishwasher.
The following minimum water 
temperatures are recommended:
MH-60 with built-in 40° rise electric
booster (Minimum 140°F/60°C)
(Min./Max. flow pressure 
20-22 PSI/138-151.8 kPa)
MH-60 with built-in 70° rise electric
booster (Minimum 110°F/43°C)
(Min./Max. flow pressure 
20-22 PSI/138-151.8 kPa)
MH-6N without built-in booster
(Minimum 180°F/70°C)
(Min./Max. flow pressure 
20-22 PSI/138-151.8 kPa)
MH-6L low temperature 
(Minimum 120°F/49°C-
140°F/60°C Optimum)
(Min./Max. flow pressure 
20-22 PSI/138-151.8 kPa)
Refer to Figs. 5 and 6
12"
[305mm]
FLOOR
12"
[305mm]
FLOOR