CMA Dishmachines CMA-180UC Manual De Usuario

Descargar
Página de 25
Operation  
PROBLEM LIKELY 
CAUSE 
SOLUTION 
Turn up supply water heater 
Low incoming water temperature 
(below 140° F) 
Insulate supply water pipe 
Thermostat out of adjustment 
Adjust thermostat 
Cold water mixing with supply 
Isolate hot water from cold 
water 
Low heat during operation 
Defective heater 
Replace heater 
P/N: 15517.00
Pressure regulator out of 
adjustment 
Adjust pressure regulator 
Low rinse water pressure 
Defective pressure gauge (actual 
pressure is okay) 
Replace pressure gauge 
P/N: 13605.45
Insufficient water supply flow 
Supply larger supply line 
Regulator at maximum but 
rinse pressure still low 
Defective water solenoid valve 
Replace water solenoid valve 
P/N: 03603.10
Low rinse water pressure 
See “Low rinse water 
pressure” in 
PROBLEM
 
column 
Low rinse water flow 
Limed up rinse arm spray nozzles  De-lime rinse arm nozzles 
Defective water solenoid valve 
Replace water solenoid valve 
P/N: 03603.10
No rinse water flow 
Defective (Rinse Relay) ice cube 
relay 
Replace ice cube relay  
P/N: 00631.00
Rinse water runs with door 
open 
Defective reed switch 
Replace reed switch 
P/N: 00557.55
Drain hose is kinked 
Un-kink drain hose 
Drain hose is not properly 
elevated before dropping to drain 
(if drain pump is used) 
Elevate drain hose 12 to 16” 
above pump before dropping 
to drain 
Defective timer assembly 
Replace timer assembly* 
P/N: 14408.80
Water overflows scrap tray 
onto floor 
Defective drain pump 
(if drain pump is used) 
Replace drain pump 
P/N: 15503.00
Defective start switch (cycle light 
will not light either) 
Replace start switch 
P/N: 15521.00
With power on, activating 
start switch does not begin 
cycle 
Defective timer assembly 
Replace timer assembly* 
P/N: 14408.80
*The timer assembly motor (
P/N: 00501.00
) or micro switches (
P/N: 00411.00
) can be replaced 
independently if that’s the only component that’s failed. 