CMA Dishmachines CMA-180UC Manual De Usuario

Descargar
Página de 25
Getting Started   
i. 
Run an appropriate length of ½” conduit from your dispenser to the mounting 
plate where it will be secured.  The conduit needs to be of sufficient length 
and flexibility to permit the machine to be moved for cleaning without having 
to disconnect any wiring. 
ii.  Run your dispenser wires from the conduit through the enclosed area across 
the top of the machine and feed them through the access hole provided in 
the back of the control panel drawer. 
2.  With the machine’s power “OFF”, connect your detergent and rinse dispenser 
wires to the power block supplied and labeled (“DISPENSER 110V - 3 AMPS 
MAX”) inside the control panel drawer.  See Figures 2.2.3a, and Figure 2.2.3c. 
Connect detergent wires to red terminals and rinse wires to blue terminals. 
3.  Remove the plug from the mixing chamber located by the vacuum breaker on the 
back of machine and install the rinse injection fitting (supplied with your 
dispenser).  See Figure 2.2.3b. 
4.  A 7/8" detergent injection hole is provided in the back of the wash tank.  Remove 
the S.S. plug and install the detergent fitting7.   
5.  The final step of installing BETA Detergent and Rinse Dispenser is titration 
adjustment by adjusting the detergent and rinse settings. The Quick Installation 
Guide supplied with Beta dispenser shows how to that.  
 
 
 
 
 
 
 
 
 
Figure 2.2.3
    Figure 
2.2.3
 
 
 
                                    (Dispenser wire connections) 
 
                                                 Figure 2.2.3c  
 
 
 
 
MODEL CMA-180UC INSTALLATION & OPERATION MANUAL Rev. 1.13 
Page 
6