CMA Dishmachines GL-X Manual De Usuario

Descargar
Página de 19
 
1.2. GL-X 
Operational 
Cycle 
 
The GL-X Operational Cycle has a total cycle time of 2 minutes (120 seconds).  The 
Timing Diagram and the steps listed below detail the individual functions that are 
executed during each Operational Cycle. 
 
Seconds:
 
 
 
0  10  20 30 40  50 60 70  
80  90 100 
110 
120 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
WASH 
RINSE 
DRAIN 
Instant 
Start Relay 
Cam 1 
Start/Stop
Cam 2 
Detergent
Drain/Rack 
Counter 
Cam 3 
Cam 4 
Flush/Fill 
Cam 5 
Sanitizer
Cam 6 
Rinse
Pump Motor
Cam 7 
Heater* 
Cam 8 
 
 
1.  With the machine powered on, toggling the START switch begins a cycle. 
a)  Toggling the START switch energizes both the cam timer motor and the instant 
start relay.  The instant start relay latches ON the power to the cam timer motor so 
that the START switch can be released a moment after it has been toggled without 
the cam timer motor losing power. 
b)  After about 2 seconds, Cam 1—the Start cam—latches ON the power to the cam 
timer motor and drops out the instant start relay. The cam timer motor continues to 
run for a total of 2 minutes, at which time it switches OFF—resetting the cam 
timer—and waits for the next start command. 
2.  Cam switch 7 controls the pump motor. The pump motor comes ON at the beginning 
of the operational cycle and continues to run until the end of the drain function 
(controlled by cam switch 3), at which time it turns off for about eight seconds 
allowing time for the machine to refill enough to avoid running the pump dry before 
the pump motor restarts and runs to the completion of the operational cycle. 
MODEL GL-X INSTALLATION & OPERATION MANUAL Rev. 1.01 –08/04/05                                                       PAGE                                        
  
3