BLANCO BID11 Manual De Usuario
![BLANCO](https://files.manualsbrain.com/attachments/e93c17503dd425abb290f398bc2057a61c087cc7/common/fit/150/50/27d96a33a0d7b45f741a73cdcb5c9cd62a011f493240a969f2c5dc62f554/brand_logo.png)
23
EN
13/ IF OPERATING ABNORMALITIES OCCUR
• BEFORE CALLING FOR SERVICE
Problem
Possible
C
auses
What to do?
The door falls heavily when
opened (integratable model)
opened (integratable model)
- Door springs not tensioned
enough to compensate for the
weight of the panel.
weight of the panel.
- Tighten the two tensioning
screws accessible in the bot-
tom section above the front
feet.
tom section above the front
feet.
The door does not stay horizontal
when open or returns too quickly
(integratable model)
when open or returns too quickly
(integratable model)
- Door springs tensioned too
much.
- No wooden panel.
- Loosen the two tensioning
screws accessible in the bot-
tom section above the front
feet.
tom section above the front
feet.
- Fit a temporary wooden panel
on the appliance and adjust
the springs.
the springs.
The door catches when closing - Appliance not stable
- Door not centred on the tub
- Adjust the feet.
- Re-centre by adjusting the
- Re-centre by adjusting the
rear feet.
The upper basket does not stay
in the high position
in the high position
- Poor manipulation (the basket
is being pulled upwards too
quickly)
quickly)
- Act more progressively (see
instructions), one side and
then the other.
then the other.
Small leak around or under the
appliance (move the appliance
to locate the leak)
appliance (move the appliance
to locate the leak)
- Leak from the tap.
- Leak from the appliance.
(Cf. table fault d07).
(Cf. table fault d07).
- Check that a seal is fitted and
retighten the nut.
- Close the water tap and call a
technician.
Small leak at the door
- Appliance not stable or not level
- Door not centred on the tub.
- Door not centred on the tub.
- Adjust the feet.
- Re-centre by adjusting the rear
- Re-centre by adjusting the rear
feet.
• SUMMARY OF THE FAULTS
Flashing LED(s)
for models without a display
Flashing LED(s)
d01 : water supply fault (tap)
d07 : overflow / anti-leak fault
d02 : draining fault
d08 : sprinkling distribution fault
d03 : heating fault
d11 : pressure sensor fault
d04 : temperature fault
d12 : filling fault (water inlet
detection system)
d05 : fault – motor under load
d13 : overheating fault
d06 : fault - motor overload
d14 : pump filling fault or insuffi-
cient flow from the water tap.