Grindmaster 115A Manual De Usuario

Descargar
Página de 24
115 & 250 Series Coffee Grinders
Page 8
Troubleshooting Guide
The following procedures must be performed by a qualified service technician.
CAUTION: Unplug the machine before cleaning or servicing the unit.
Problem
Possible Cause
Solution
Grinder will not start when START 
button is pushed
• Plug not in outlet properly
• No power to outlet
• Circuit breaker has tripped
• Install plug in outlet
• Check outlet with lamp or radio to verify 
outlet has power.
• Reset circuit breaker by pushing in reset 
button until you hear a click
Grinder runs or hums but no 
coffee is dispensed
• Shear disc is broken
• Obstruction in opening to grinding
chamber
• Auger has stalled (Models 250, 250A 
250RH-2 & 250RH-3 only).
• 250RH Models: Hoppers not properly in 
place
• Replace shear disc. See “Shear Disc
Replacement” section or instructions on
inside of upper front plate.
• Remove hopper and clear obstructions.
• Clean auger
• Make sure hoppers are seated in their 
allocated area
Excessive amount of chaff flying
about
• Defective chaff mixer spring
• Static electricity
• If bent, broken, or missing, 
replace spring.
• If stuck open with coffee, clean coffee to 
free spring
• Tighten all nuts, bolts, and screws and 
verify outlet is grounded.
Quantity of coffee dispensed each
throw is not the same
• Auger stalls (Models 250, 250A, 
250RH-2, and 250RH-3 only)
• Timer delay is not working or running 
long enough
• Defective timer
• Refer to problem as listed below in this 
Troubleshooting Guide.
• See “Timer Adjustment” section
• Check the length of time the grinder 
runs
• If time varies more than plus or minus 
1%, replace timer.
Knobs do not operate smoothly
• Coffee beans or bean dust may have 
clogged carrier
• With machine unplugged, clean carrier
Auger does not turn
• Coffee beans or bean dust may have 
jammed auger
• 250RH Models: Hopper not properly 
seated
• With machine unplugged, clean auger 
opening
• Make sure hopper is seated in its 
designated area (see Figure A)
Auger will not operate
• Motor or link is binding
• Auger motor has burned out
• Wiring harness to motor is loose
• 250RH Models: Hopper not properly 
seated
• Check all alignment of link and motor. 
Check tightness of motor mounting 
screws.
• Replace motor
• With machine unplugged, check to see 
if wires are connected to motor
• Make sure hopper is seated in its 
designated area (see Figure A)
Circuit breaker continuously trips
• Insufficient current due to use of 
extension cord
• Insufficient current due to overloaded 
line
• Grind setting needs adjustment
• Plug unit directly into outlet. Do not use 
extension cord.
• Designate single line for grinder. Do not 
use multi-outlet box.
• Adjust grind to coarser setting (see 
“Grind Adjustment” section)
continued on next page