Mounting
The hob unit can be mounted  in any 
type of kitchen with a table surface 
whose thickness is between 28 mm and 
40 mm.
Fixing  
Unscrew the fixing brackets just enough 
so they may be turmed. Fasten the 
brackets to the worktop with a screw 
driver.
Cut-out measurements
One rectangular hole is sawn out for the 
hob combination chosen.
The depth of the cut-out for any unit is: 
490 mm
Length of hole = sum of all units` 
externally measured lenght, less 20 mm.
Mounting of Reinforcement 
Beams
A reinforcement Beam, with supporting 
flanges at each end, is included with 
each two-burner unit. For unit 
combinations, a reinforcement beam 
must be used between each unit. It is not 
necessary to attach the reinforcement 
beam to the table surface, as it is held in 
place by a specially designed moulding, 
which is incorporated in the hob unit´s 
flanges.
Minimum distance
to wall:
150 mm
Minimum distance
to wall (non-
flammable material):
150 mm
Reinforcement
beams
Minmum distance to
any shelf underneath
shall be 245 mm +
room enough for a
bowl that can take at