Recirculation version air outlet 
• Fix  the connection 15 to the frame using the 4 
screws provided. 
•  Fix the flange 10 to the lower opening of the connec-
tion 15
 
•  Connect the hood air outlet to the flange in the lower 
part of the junction using a rigid or flexible ø 150 
tube (by installer’s choice). 
 
15
10
 
Flue assembly - Mounting the hood body  
•  Position the upper chimney section and fix the upper 
part to the frame using the 2 screws 12c (2,9 x 6,5) 
provided. 
•  Similarly, position the lower chimney section   and 
fix the lower part to the frame using the 2 screws 12c 
(2,9 x 6,5) provided. 
 
Before fixing the hood body to the frame: 
•  Remove the grease filters from the hood body. 
•  Remove any activated charcoal filters. 
• From below, use the 4 screws 12f    (M6  x 
10)provided to fix the hood body to the frame. 
 
12f
12c