Low Profile – 1600 Advantage Series Service Manual – International
 
 
 
 
 
Fuse holder 
 
 
Check, replace if necessary. 
 
 
 
 
Gas pressure switch 
 
Check for supply voltage to neutral 
 
 
 
 
(internal to gas valve)   
on both sides of switch. If voltage is 
 
 
 
 
 
 
 
 
present on one side of switch only, 
 
 
 
 
 
 
 
 
check the following. Check for proper  
 
 
 
 
 
 
 
 
gas pressure supply to gas valve.(Marked  
 
 
 
 
 
 
 
 
on oven spec. plate.) Check for proper  
 
 
 
 
 
 
 
 
adjustment of gas pressure switch.  
 
 
 
 
 
 
 
 
should be set at 10 Nat., 27 for L.P. 
 
 
 
 
 
 
 
 
 
or 4.5 for town gas. Check gas filter in  
 
 
 
 
 
 
 
 
gas valve for blockage or damage. (See 
 
 
 
 
 
 
 
 
Adjustment section for location.) 
 
 
 
 
 
 
 
 
If the above checks OK, but switch is 
 
 
 
 
 
 
 
 
still not closed replace gas valve. 
 
 
 
 
Oven air pressure switch 
 
Check for supply voltage on both sides 
 
 
 
 
 
 
 
 
of switch. If voltage is present on one  
 
 
 
 
 
 
 
 
side only, check for air tube blockage. 
 
 
 
 
 
 
 
 
Adjust air pressure switch. If the above 
fails, replace air pressure switch. 
 
 
 
 
Hi-limit thermostat 
 
Terminals are normally closed. If open, 
 
 
 
 
 
 
 
 
reset and test oven for proper operation.  
 
 
 
 
 
 
 
 
If thermostat will not hold for maximum 
 
 
 
 
 
 
 
 
oven temperature, and oven is not  
 
 
 
 
 
 
 
 
exceeding maximum temperature dial  
 
 
 
 
 
 
 
 
setting, check for proper location of 
 
 
 
 
 
 
 
 
capillary bulb in its spring holder. 
 
 
 
 
 
 
 
 
If above checks OK, replace hi-limit. 
 
 
 
 
Ignition control   
 
Check for supply voltage to ignition  
 
 
 
 
 
 
 
 
control at terminal #1 and neutral. 
 
 
 
 
 
 
 
 
If voltage is not present, trace wiring  
 
 
 
 
 
 
 
 
back to hi-limit thermostat. Check for  
 
 
 
 
 
 
 
 
supply voltage at terminal #6 to neutral. 
 
 
 
 
 
 
 
 
If no voltage is present, wait 30 seconds 
 
 
 
 
 
 
 
 
and check reset button. If above fails,  
 
 
 
 
 
 
 
 
replace ignition control. 
 
 
 
 
Burner reset switch 
 
Switch is normally open. Check to see 
 
 
 
 
 
 
 
 
that the switch closes when reset button  
 
 
 
 
 
 
 
 
is pushed. Replace as needed. 
 
 
 
 
Burner blower motor 
 
Check for supply voltage to burner  
 
 
 
 
 
 
 
 
blower motor. 
 
 
 
 
 
 
 
 
WITH POWER OFF: Turn blower  
 
 
 
 
 
 
 
 
wheel to check for locked rotor. If  
 
 
 
 
 
 
 
 
supply voltage is present and motor does  
 
 
 
 
 
 
 
 
not run, replace motor. 
 
 
 
 
Burner blower motor 
 
Check for supply voltage switching to 
 
 
 
 
Air pressure switch 
 
terminal N. O. as the air pressure switch 
 
 
 
 
 
 
 
 
closes. Check for air tube blockage or 
 
 
 
 
 
 
 
 
misalignment, adjust air pressure switch. 
 
 
 
 
 
 
 
 
If the above fails, replace air pressure 
 
 
 
 
 
 
 
 
switch. 
 
 
 
 
Spark generator  
 
After a pre-purge time of 30 to 60  
 
 
 
 
 
 
 
 
seconds after blower motor starts, 
 
 
 
 
 
 
 
 
check for supply voltage to spark 
 
 
 
 
 
 
 
 
generator. If voltage is not present, 
 
 
 
 
 
 
 
 
Check reset button located on rear of  
 
 
 
 
 
 
 
 
control box. If voltage is still not 
 
 
 
 
 
 
 
 
present, replace ignition control. 
 
 
 
 
 
 
 
 
If voltage is present, visually check  
 
 
 
 
 
 
 
 
for spark at igniter head. 
 
 
 
 
Igniter/sensor assembly  
Check for visible damage to igniter/ 
 
 
 
 
 
 
 
 
sensor assembly. If there is no visible 
 
 
 
 
 
 
 
 
damage to the components, and no spark,