GAS CONVECTION OVEN "GAS SPECIFICATIONS” 
 
 
 
TOTAL 
MAIN 
BURNER 
 
ORIFICE 
 
PILOT 
PILOT 
ORIFICE 
GAS  
PRES. W/C 
 
B.T.U.'S 
ORIFICE 
AMT. 
ORIFICE 
AMT. 
NAT     PRO 
 
 
 
NAT 
 
PRO 
 
 
NAT 
 
PRO 
 
** 
 
 
 
MCO 
 
 
40,000 
 
5
/
64
” 
(.0781”)
 
 
#55 
 
 
.020" 
 
.012" 
 
4.5" 
 
5.0” 
 
10.0" 
 
MCO 
 
 
60,000 
 
5
/
64
” 
(.0781”)
 
 
#55 
 
 
.020" 
 
.012" 
 
4.5" 
 
5.1” 
 
10.0" 
 
MCO 
 
 
80,000 
 
5
/
64
” 
(.0781”)
 
 
#55 
 
 
.020" 
 
.012" 
 
4.5" 
 
5.5” 
 
10.0" 
 
* - Gas pressure measured at burner manifold.  ** - Gas pressure measured at redundant gas valve 
pressure tap. 
 
All models (single deck ovens) amperage rating is 6.2 (each oven).  Manifold size is ¾" N.P.T. (National 
Pipe Thread). NOTE:  Two-speed motor, 1140 and 1725 R.P.M., 60 Hz, clock-wise motor rotation looking 
into oven cavity. NOTE:  Each deck supplied with a 6 ft. power supply cord for 120-volt units. 
 
DIMENSIONS & SPECIFICATIONS 
 
 
 
 
 
38
6-1/2
32
32
70-1/2
19
32
35-9/16
3/4 N.P.T.
GAS INLET
1-1/2
[813mm]
[483mm]
[903mm]
[38mm]
[1791mm]
[165mm]
[813mm]
[813mm]
[19mm]
[965mm]
2-3/8 x 5
7-3/4
38-1/4
1-7/16
17-3/4
[48mm]
REAR GAS INLET
39-1/4 STD
43-1/4 DEEP
1-7/8
[197mm]
[37mm]
[60mm x 127mm]
FLUE
[1099mm] DEEP
[997mm] STD
[972mm]
[451mm]
25-1/2
57-1/2
32
38
54-9/16
1/2 N.P.T.
GAS INLET
1-1/2
[38mm]
[813mm]
38
[965mm]
[965mm]
[1461mm]
[648mm]
[1386mm]
[13mm]
Single Deck 
(Front View)
Double Deck 
(Front View)
(Top View)
 
 
INTERIOR DIMENSIONS (per oven) 
EXTERIOR DIMENSIONS 
SHIP WEIGHT/DIM 
Model # 
H (w/legs) 
Lb./KG 
Cu. Ft. 
MCO-GS-10 
29”(736mm) 
24”(610mm) 
24”(610mm) 
38”(965mm) 
57½”(1460mm) 
39”(991mm) 
510/232 
42 cu. ft. 
MCO-GS-20 
29”(736mm) 
24”(610mm) 
24”(610mm) 
38”(965mm) 
70½”(1791mm) 
39”(991mm) 
1020/464 
84 cu. ft. 
MCO-GD-10 
29”(736mm) 
24”(610mm) 
28”(711mm) 
38”(965mm) 
57½”(1460mm) 
43”(1092mm) 
510/232 
42 cu. ft. 
MCO-GD-20 
29”(736mm) 
24”(610mm) 
28”(711mm) 
38”(965mm) 
70½”(1791mm) 
43”(1092mm) 
1020/464 
84 cu. ft. 
 
 
INPUT CHART - Natural or Propane Gas 
ELECTRICAL CHARACTERISTICS 
 
Model # 
 
BTU/HR 
KW 
Equiv. 
 
Gas Inlet 
 
120V/1 Phase 
 
240V/1 Phase 
 
Motor 
MCO-GS-10 
60,000 
17.6 
One @ ¾” NPT 
One @ 6.2 Amps 
One @ 3.1 Amps 
½ HP 
MCO-GS-20 
120,000 
35.2 
One @1” NPT 
Two @ 6.2 Amps 
Two @ 3.1 Amps 
½ HP 
MCO-GD-10 
60,000 
17.6 
One @ ¾” NPT 
One @ 6.2 Amps 
One @ 3.1 Amps 
½ HP 
MCO-GD-20 
120,000 
35.2 
One @ 1” NPT 
Two @ 6.2 Amps 
Two @ 3.1 Amps 
½ HP 
SECTION 2: OVERVIEW OF OPERATIONAL SEQUENCES