UF-1 and UFB-1 Valves Training Manual
- 16 -
© 1999-2005, IMI Cornelius Inc.
INSTALLATION
CAUTION — Only trained and certified technicians should service this 
unit. ALL WIRING AND PLUMBING MUST CONFORM TO 
NATIONAL AND LOCAL CODES.
1. I
NSTALLATION
 R
EQUIREMENTS
1.1 Requirements Summary
The beverage dispenser that the UF-1 or UFB-1 valve(s) will be installed on should 
be capable of supplying an adequate flow of water (for the beverage and for cool-
ing) and syrup.
environment:  . . . . . . .indoor installation only
temperature: . . . . . . . .50 to 110
°
 F ambient temperature
syrup BIB: . . . . . . . . .60 to 80 psi
carbonated water: . . . .65 to 110 psi
plain water:. . . . . . . . .50 to 110 psi
electrical: . . . . . . . . . .24 volts AC (22-27 volts), 80 VA, 50/60 Hz 
1.2 Electrical Requirements
Before connecting electrical power to the beverage dispenser refer to nameplate to 
see if it requires 50 or 60 Hz power. 
DANGER — 
To avoid possible serious injury or death the ELCB (earth leakage 
circuit breaker) must be installed in the electrical circuit of all 50 Hz units.
WARNING — 
To avoid possible electrical shock the unit must be electrically 
grounded using the green grounding screw provided inside the electrical contrac-
tor box.
CAUTION — 
The wiring must be properly grounded and connected through a 
15-amp disconnect switch (slow–blow fuse or equivalent HACR circuit breaker). 
ALL WIRING MUST CONFORM TO NATIONAL AND LOCAL CODES. MAKE 
SURE UNIT IS PROPERLY GROUNDED.
2. I
NSTALLATION
 & S
TART
-
UP
 
2.1 UF-1 and UFB-1 Valve Installation Procedure
1. Shut off syrup, unplug carbonator, shut off CO
2
 and water supply to the unit.
2. Release pressure in lines by activating valves and lifting relief valve of carbonator
IN
STALLATI
ON