Avanti CB350S Manual De Usuario

Descargar
Página de 28
 
12 
•  Connect the hose by inserting it into the hose outlet (to check that the hose is correctly 
connected, try to remove it by slightly pulling it. Resistance indicates that the hose is correctly 
connected. In order to disconnect the hose, push in the blue plastic collar on the hose outlet 
while pulling the hose).  See below. 
 
 
 
 
 
 
 
 
 
•  Place the face of the regulator into the opening on the door and hold it in place with the latch 
provided. 
•  Close the door. 
 
b) 255 gram (9 oz) cylinder (Accessory item, sold separately) 
 
•  A 255 gram  (9 oz) cylinder can be ordered and will dispense up to ten 5L kegs. 
•  Make sure that the pressure gauge valve is shut (to shut the valve, turn it 
counterclockwise). 
•  Screw the gas cartridge on the pressure gauge until fit is tight and firm. 
•  Connect the hose by inserting it into the regulator hose outlet (to check that the hose is 
correctly connected, try to remove it by slightly pulling it. Resistance indicates that the hose is 
correctly connected. In order to disconnect the hose, push in the blue plastic collar on the 
hose outlet while pulling the hose).  See below. 
 
 
 
 
 
 
 
 
 
 
•  Place the assembly into the housing provided, making sure that the pressure gauge dial is in 
front of the window and close the latch. 
•  Close the door. 
 
 
Adjusting the gas pressure 
 
Beer type 
CO2 content in % 
Pressure in bar approx. 5°C 
German beers 
+/- 0.5 
+/- 0.4 à 0.5 bars 
French beers 
+/- 0.6 à 0.8 
+/- 0.8 bars 
Very fermented brown ales 
+/- 0.6 à 0.8 
+/- 0.8 à 1 bars