Crane Merchandising Systems 675 Manual De Usuario
HDC II Programming Guide
Test the Machine
July, 2003
66
6730018
RINSE THE BREWER
1.
Press
, then press
until the display shows
BREW RINSE.
2.
Press
to rinse the brewer. The display shows
RINSING until the oper-
ation is complete.
3.
CONTINUE.
TEST SWITCHES OR SENSORS
1.
Press
, then press
until the display shows
IN.MKPHL12.
2.
Actuate each switch or sensor to test its function:
As you actuate each input, the display element representing that switch
blinks on. Releasing the switch causes that element to blink off again.
blinks on. Releasing the switch causes that element to blink off again.
3.
CONTINUE.
VIEW SUREVEND™ LAST RECORDED
CALIBRATION VALUE
CALIBRATION VALUE
1.
Press
SureVend until the display shows
CAL.LST XXX. XXX can be
any number from 0 to 255, and represents the most recent value read from
the sensor. The lower the number the greater the sensor blockage. A num-
ber of 255 means that there is a fatal problem with the SureVend™ interface
board. Ensure the SureVend™ interface PCB is properly connected to the
main controller PCB.
the sensor. The lower the number the greater the sensor blockage. A num-
ber of 255 means that there is a fatal problem with the SureVend™ interface
board. Ensure the SureVend™ interface PCB is properly connected to the
main controller PCB.
2.
CONTINUE.
M = mug/cup sensor (if equipped)
K = freevend keyswitch
P = waste pail switch
H = high water tank level switch
L = low water tank level switch
1 = ring 1 cup sensor switch
2 = ring 2 cup sensor switch