Haier HBF05E Manual De Usuario
English
18
Cause 2
Improper drawing of beer into the glass.
Correction
• Open the faucet quickly and completely.
• Proper foam should be a tight creamy head. The collar on the average glass
Improper drawing of beer into the glass.
Correction
• Open the faucet quickly and completely.
• Proper foam should be a tight creamy head. The collar on the average glass
should be 3/4" to 1" high. Beer drawn without head has the appearance of
being flat.
being flat.
Cause 3
Not enough pressure.
Correction
• Increase the pressure if beer runs too slowly. The correct flow should fill a 10oz.
Not enough pressure.
Correction
• Increase the pressure if beer runs too slowly. The correct flow should fill a 10oz.
glass in 4 seconds. (Approx. 8oz. of liquid)
• Check the pressure source to determine whether there are obstructions in the air
line.
• Replace a sluggish air source or the CO
2
regulator and gauge.
• The tank pressure must always be higher than the pressure used on the keg.
• Always apply pressure to the keg before drawing beer.
• Always apply pressure to the keg before drawing beer.
Beer Condition: Loose Foam
Large soap-like bubbles that settle quickly.
Large soap-like bubbles that settle quickly.
Cause 1
This is generally the same as the Flat Beer condition. See the Flat Beer
causes above.
This is generally the same as the Flat Beer condition. See the Flat Beer
causes above.
Beer Condition: Off-Taste Beer
Often bitter and bitey; sometimes completely lacking in flavor and zest. May
also have an oily or foul odor, which carries an unpleasant taste.
Often bitter and bitey; sometimes completely lacking in flavor and zest. May
also have an oily or foul odor, which carries an unpleasant taste.
Cause 1
Improper cleaning of the tap.
Correction
• Brush and clean the tap properly. It should be scoured using a detergent, then
Improper cleaning of the tap.
Correction
• Brush and clean the tap properly. It should be scoured using a detergent, then
rinsed clean.
Cause 2
Contaminated air line.
Correction
• Air line should be examined. If contaminated, it should be replaced.
Contaminated air line.
Correction
• Air line should be examined. If contaminated, it should be replaced.