TROUBLESHOOTING (cont.)
Inconsistent beverage level in 
dispenser
Consistently low beverage level 
in the dispenser 
Spitting or excessive steaming
1. Strainer /flow control             
(If equipped)
2. Syphon System
3. Lime Build-up
CAUTION - Tank and tank com-
ponents should be delimed 
regularly depending on local 
water conditions. Excessive min-
eral build-up on stainless steel 
surfaces can initiate corrosive 
reactions resulting in serious 
leaks.
4. Water Pressure 
1. Timer
2. Strainer/flow Control  
 
(If equipped)
1. Lime Build-up
CAUTION - Tank and tank com-
ponents should be delimed 
regularly depending on local 
water conditions. Excessive min-
eral build-up on stainless steel 
surfaces can initiate corrosive 
reactions resulting in serious 
leaks.
(A) Direction of flow arrow must 
be pointing towards the brewer.
(B) Remove the strainer/flow 
control and check for obstruc-
tion. Clear or replace.
The brewer must be level or 
slightly lower in front to syphon 
properly.
Inspect the tank assembly for 
excessive lime deposits. Delime 
as required.
The water pressure to the brewer 
must be at least 20 psi (138kPa) 
and minimum 1.0 gpm flow rate.
Timer dial must indicate at least 
two minutes and fifteen seconds.
Refer to Operating Manual.
(A) Direction of flow arrow must 
be pointing towards brewer.
(B) Remove the strainer/flow 
control and check for obstruc-
tions. Clear or replace.
Inspect tank assembly for exces-
sive lime deposits. Delime as 
required.
PROBLEM
PROBABLE CAUSE
REMEDY