REFILL - Range: 20 to 230
  This function allows the operator to adjust the 
sensitivity of the refill circuit. This is mainly a trouble-
shooting feature. Water in different geographical loca-
tions can have different conductivities. By adjusting 
the sensitivity of the refill circuit, this will allow the 
brewer to operate under various water conditions.
Procedure to set the sensitivity threshold of the 
refill circuit:
NOTE: Make sure the water in the tank is touching 
the refill probe.
1.  Press and hold upper right hidden switch until the 
display reads UNITS. Release switch.  Continue to 
press and release switch until the display reads 
REFILL and shows a number on both sides of the 
word.
2.  To adjust the threshold setting, press (-) to de-
crease, or (+) to increase the setting.
NOTE: Always make sure that the number on the right 
is larger than the number on the left when water is in 
contact with the refill probe in the tank.
3.  When finished, press and release DONE. This 
saves the new setting and advances to the next 
function screen:
  SPR
Y OZ/M (SINGLE brewers)
 
L SPRY OZ/M (DUAL brewers). Another alternative 
is to press and release the ON/OFF switch (either on 
DUAL brewers) located on the front switch panel 
to exit REFILL and return to the MAIN SCREEN.
Procedure to set ready temperature:
1.  Press and hold upper right hidden switch until the 
display reads UNITS. Release switch.  Continue to 
press and release switch until the display reads 
SET READY.
2.  To adjust the ready temperature, press the (-) 
button to decrease, or (+) to increase the ready 
temperature.
3.  When finished, press and release DONE to save 
the new setting, exit the SET READY function and 
advance to the next function screen, REFILL. 
Another alternative is to press and release the 
ON/OFF switch (either on DUAL brewers) located 
on the front switch panel to exit the SET READY 
function and return to the MAIN SCREEN.
2.  To adjust the brew temperature, press (-) to de-
crease or (+) to increase the brew temperature.
3.  When finished, press and release DONE to save 
the new setting, exit the SET TEMP function and 
advance to the next function screen,  SET READY. 
Another alternative is to press and release  the ON/
OFF switch (either on DUAL brewers) located on 
the front switch panel to exit the SET TEMP func-
tion and return to the MAIN SCREEN.
SET READY - Range: 185˚F (85˚C) to 203˚F (95˚C)
 
This function allows the operator to set the mini-
mum temperature allowable to start a brew cycle. The 
range can be from 185˚F (85˚C) to within 2˚F (-1.7°C) 
of the SET TEMP. The water must be at the SET READY 
temperature or higher for the display to indicate READY 
TO BREW. If brew lockout is enabled, the brewing pro-
cess will not start below this READY temperature.
NOTE: The upper limit for SET READY temperature 
is 2˚F (-1.7°C) less than the water temperature (SET 
TEMP) setting.
SET READY: XXX°
 (-)  DONE  (+)
XXX REFILL -> XXX
 (-)  DONE  (+)
SET TEMP (cont.)