Bunn LCR-2 Manual De Usuario

Descargar
Página de 36
18
 
MENU SCREEN 
 ACTION 
   DESCRIPTION
BIB EMPTY -> 500
(-)     EXIT     (+)
XX   REFILL -> 155
(-)   EXIT   (+)
WTR START DELAY
(-)  .15SEC  (+)
WTR STOP DELAY
(-)  .15SEC  (+)
TEST LED’S  ?
NO   EXIT   YES 
TEST SWITCHES  ?
UseSwitchToTest
TEST REFILL  ?
         EXIT  YES
TEST  HEATER   ?
         EXIT  YES
ENTER ASSET #
(-) 000000 (+)
SERIAL #
LCR 0000000
FACTORY DEFAULTS
NO         YES
Use the (+) or (-) buttons to 
adjust empty BIB threshold
Use the (+) or (-) buttons to 
adjust Refill threshold
Use the (+) or (-) buttons to 
adjust delay time
Use the (+) or (-) buttons to 
adjust delay time
Select (YES) or (NO)
NONE
Momentarily depress (YES)
Momentarily depress (YES)
Use the (+) or (-) buttons to 
adjust the ASSET NUMBER
NONE
Select (YES) or (NO)
Used to set the Conductance Threshold for the 
Empty BIB warning. Default is 500
Used to set the Conductance Threshold for the 
Tank Refill Probe.
Dispense Valve ON Delay. Eliminates weak mix 
at the beginning of a dispense.
Dispense  Valve  OFF  Delay.  Flushes  the  mix 
chamber at the end of a dispense.
LED diagnostics. Selecting YES will light all Front 
Door LED’s.
Switch Diagnostic: Activate switches separately to 
test. Display will indicate which Switch has been 
activated. NOTE: Door Interlock switch must be 
held closed.
Refill Valve Diagnostic: Press YES to momentarily 
energize the Solenoid. CAUTION: Inlet Valve will 
open and water will flow, if connected and turned 
ON.
Tank Heater Diagnostic: Press YES to momentarily 
energize the Tank Heater Circuit.
CAUTION: AC power will be applied to the Tank 
Heater Circuit.
Allows the user the option of entering an Asset 
Number. Default is 000000
Displays the manufacture’s Serial Number (should 
be identical to the Serial Number on the machine 
Data Plate)
CAUTION:  Selecting  YES  will  RESET  all 
Programming Functions to the Factory Default 
settings. NOTE: On LCC Models the Chiller will 
have to be reset to the ON condition, (see Chilled 
Unit programming function).
36026 061605