DRIP TIME (used on brewers with funnel locks)
This function allows the setting or modification of
the  funnel  locks  to  stay  engaged  after  the  end  of  a
brew  cycle.  This  ensures  that  the  funnel  cannot  be
removed until after the liquid has emptied out of the
funnel.
Procedure to modify drip times:
Range: OFF to 10 minutes for all three batch sizes.
NOTE:  If  the  brewer  is  already  in  the  DRIP  TIMES
screen, it is not necessary to follow steps 1 through 10
in this section, but proceed directly to step 11.
1. Press and hold the ® pad until the display reads
SET NEW RECIPES. Release the ® pad. Press the
® until the display reads REVIEW RECIPES.
2. Press  YES  to  proceed.  The  display  should  now
read NO NAME, along with MODIFY, SHOW and
NEXT.
3. Press and release NEXT to advance to the desired
coffee name to be modified.
4. Press  and  release  MODIFY.  The  display  should
read BREW OZ.
5. Press and release DONE. The display should read
3 BATCHES DONE?.
6. Press and release YES. The display should now
read % BYPASS.
7. Press and release DONE. The display should read
3 BATCHES DONE?.
8. Press and release YES. The display should now
read SET PULSE BREW.
9. Press  and  release  NO.  The  display  should  now
read SET PREINFUSION.
10. Press  and  release  NO.  The  display  should  now
read DRIP TIME, along with either the word OFF,
or a time will be showing. A batch light should also
be blinking.
11. Using the (-) and (+), set the amount of time from
when the brew solenoid shuts off to when drip-out
occurs for that batch size.
NOTE: Set to OFF to prevent funnel locks from engag-
ing  (to  disable  this  function),  for  a  particular  batch
size. To set to OFF, press and release (-) until OFF is
displayed.
P2447