PROGRAMMING FUNCTIONS - LEVEL 2 (cont.)
SERVICE TOOLS (cont.)
Testing individual components (outputs):
This will allow the operator to test the operation of
individual components and outputs of the brewer.  The
components  that  can  be  individually  tested  are  as
follows:
Brew Valve
Bypass Valve
Funnel Lock
Server
Refill Valve
Tank Heaters
Procedure to test components (outputs):
1. Place brew funnels into rails on the brewer.
2. Place a Soft Heat
®
 server beneath the brew funnel.
3. Press and hold the ® pad until the display reads
SET NEW RECIPES. Release the ® pad. Continue
pressing  and  releasing  the  pad  until  SERVICE
TOOLS
 appears.
4. Press YES to run tests on various components and
outputs within the brewer. Pressing NO will exit
this  function  and  advance  to  the  next  function
screen.
5. The display should read TEST OUTPUTS.
6. Press and release YES. The display should read
BREW VALVE.
7. To test BREW VALVE, press ON. If the brew valve
is functional, water should run from the brewer.
8. Press OFF to end flow of water.
9. Press NEXT to advance to the next component to
be tested.
NOTE: To bypass testing any component, press NEXT
to advance to the next one, without testing the previ-
ous component.
10. To test BREW BYPASS, press ON. If the bypass
valve  is  functional,  water  should  run  from  the
brew bypass.
11. Press OFF to end flow of water.
12. Press NEXT to advance to the next component to
be tested.
13. To test FUNNEL LOCK, press ON. If the funnel lock
is functional, the lock will come down to hold the
funnel in place.
14. Press OFF to retract the funnel lock.
15. Press NEXT to advance to the next component to
be tested.
16. To test SERVER, press ON. If the server and the
sensor are functional, the light on the lower right
corner of the server will illuminate.
17. Press OFF to end testing of server.
18. Press NEXT to advance to the next component to
be tested.
19. To test REFILL VALVE, press ON. If the refill valve
is functional, the sound of the valve operating will
be heard.
20. Press OFF to end testing of refill valve.
21. Press NEXT to advance to the next component to
be tested.
22. To test TANK HEATER, connect a voltmeter to the
tank heater to check for voltage.
23. Press ON. The correct voltage should be present at
the heater terminals.
24. Press OFF to end testing of the tank heaters.
NOTE: The tank heater will automatically turn off if left
on too long.
25. After testing the tank heater, press NEXT to ad-
vance to the next test.
26. The SPARE TRIAC is reserved for future use.
27. Press NEXT to return to TEST OUTPUTS.
28. To  exit  SERVICE  TOOLS,  press  the 
  pad
located on the front switch panel. This will return
to the MAIN SCREEN.
Procedure to test switches:
This function allows the operator to test the opera-
tion of the individual switches on the front panel.
1. Place brew funnels into rails on the brewer.
2. Place a Soft Heat
®
 server beneath the brew funnel.
3. Press and hold the ® pad until the display reads
SET NEW RECIPES. Release the ® pad. Continue
pressing and releasing the ® pad until SERVICE
TOOLS
 appears.
4. Press YES to run tests on various components and
outputs within the brewer. (Pressing NO will exit
this  function  and  advance  to  the  next  function
screen.)
34025  100501