Page 26
P1598
4.
Disconnect the brewer from the power source.
If voltage is present as described, proceed to #5.
If  voltage  is  not  present  as  described,  refer  to  the
wiring diagrams and check the brewer wiring harness.
5.
Reconnect the blue wire to terminal 1.
6.
Carefully  connect  a  piece  of  insulated  jumper
wire to terminal 4. Keep the other end of this wire
away from any metal surface of the brewer.
7.
Check the voltage across terminals 1 & 3 with a
voltmeter.  Connect  the  brewer  to  the  power
source.Turn  the  "ON/OFF"  switch  to  the  "ON"
position The indication must be:
a.)  120  volts  ac  for  three  wire  120/208  volt
models and three wire 120/240 volt models after
a delay of approximately 5 seconds.
b.) 200 to 240 volts ac for two wire 200 or 240
volt  models  after  a  delay  of  approximately  5
seconds.
8.
Touch the free end of jumper wire to the brewer
housing. The indication must be 0.
9.
Move the jumper wire away from the brewer
housing. The indication must again be:
a.)  120  volts  ac  for  three  wire  120/208  volt
models and three wire 120/240 volt models after
a delay of approximately 5 seconds.
b.)  200  to  240  volts  ac  for  two  wire  200  or
240volt models after a delay of approximately 5
seonds.
10. Disconnect  the  brewer  from  the  power  source
and remove the jumper wire from terminal 4.
Location:
The liquid level probe is located within the tank lid
inside the fill basin. The liquid level board is located
inside  the  rear  inspection  panel  on  the  top  left  of
component mounting bracket.
Test Procedure.
1.
Disconnect the brewer from  the power source.
2.
Remove the blue wire from terminal 1 and the
pink wire from terminal 4 of the circuit board.
3.
Check the voltage across terminals 2 and 3 with
a  voltmeter.  Connect  the  brewer  to  the  power
source.  Turn  the  "ON/OFF"  switch  to  the  "ON"
position.The indication must be:
a) 120 volts ac for two wire 120 volt models and
three wire 120/240 volt models.
b) 200 to 240 volts ac for two wire 200 volt or 240
volt models.
c) 100 volts ac for two wire 100 volt models.
FIG. 18 LIQUID LEVEL PROBE
& CONTROL BOARD
29251 052500
LIQUID  LEVEL  CONTROL  BOARD  (Models  STF  &
STFA)
SERVICE (cont.)