Bunn Titan Dual Manual De Usuario

Descargar
Página de 58
Page 47
PROBABLE CAUSE
REMEDY
PROBLEM
TROUBLESHOOTING (cont.)
Temperature Too Low
Heating Time Too Long
Fill Time Too Long
Temp Sensor Out Of Range, Check 
For Bad Connections
Temp Sensor Out Of Range, Check 
Wire For Shorts
Equipment will not operate
1.  Water  temperature  in  the  tank 
does not meet the ready tempera-
ture.
1. Tank Heater failure.
2.  Control  Board/Thermistor  fail-
ure
1. Water shut off to brewer
2. Inlet Solenoid failure
3. Control Board Failure
4. ON/OFF switch is OFF
1.  Temperature  Sensor  Probe 
wire(s) broken or not making con-
nection
1.  Temperature  Sensor  Probe 
wire(s)  shorted  to  housing  or  to 
each other.
1. No power or incorrect voltage
A) Wait for the brewer to heat to the 
proper temperature.
B)  Disable  the  BREW  LOCKOUT 
function.  See page 13 for proce-
dure.
Service required
Service required
Check water supply shut-off
Service Required
Service Required
Turn switch ON
Check wire and connection of both 
black and white wires of temperature 
probe.
Check to confirm that wire(s) are 
not pinched between two surfaces 
or connected to each other.
Measure the voltage at the terminal 
block and confirm that it matches 
the voltage specified on the brewer 
data plate withing +/- 10%.
40119 071107