Bunn SRUA Manual De Usuario

Descargar
Página de 31
Page 5
INITIAL SETUP
CAUTION - The brewer must be disconnected from the power source throughout the 
Initial Setup, except when
specified in the instructions.
IMPORTANT: Brewer must be level and installed on a sturdy structure.
Electrician's and Plumber's Instructions are provided. These instructions should be carefully
followed before proceeding with 
Initial Setup.
Be sure all electrical and plumbing connections are tight.
1. Disconnect the brewer from the power source.
2. Remove the left side panel from the hood and rotate the control thermostat knob fully counterclockwise to the
"OFF" position. Replace the side panel.
3. Connect the brewer to the power source and place the lighted ON/OFF switch in the "ON" position. Water will
flow into the tank and should automatically stop after approximately 15 minutes.
NOTE - The lighted ON/OFF switch must be in the "ON" position to automatically refill the tank. The switch should
be in the "OFF" position whenever the brewer is left unattended.
4. Disconnect the brewer from the power source.
5. Remove the left side panel from the hood and rotate the control thermostat knob clockwise to the 5 o'clock
position. Replace the side panel.
6. Connect the brewer to the power source and wait for the water in the tank to heat to the proper temperature.
This will take approximately 1-2 hours, depending on the incoming water temperature. Some water will flow
from the overflow tube during this time due to expansion. Draw off a 1/2 gallon decanter of water every 15
minutes during the initial heat-up to lessen the chance of hot water flow from this expansion.
7. Determine the water temperature by checking the water with a thermometer at the hot water faucet (red handle).
The best brewing temperature is between 195˚(91˚C) and 200˚F(93˚C). The temperature may be increased by
turning the thermostat knob clockwise and decreased by turning the knob counterclockwise.
8. When the desired temperature is attained, place the funnel support, funnel, and funnel cover on top of the coffee
reservoir. Center the discharge of the water swing spout over the opening in the top of the funnel cover.
9. Place the lighted ON/OFF switch in the "ON" position and momentarily press and release the start switch. Water
should flow from the swing spout into the funnel assembly.
10. Drain and measure the water from the reservoir when the flow of water from this initial cycle stops. If it is three
gallons, proceed to step 12. If it is more or less than three gallons, proceed to step 11.
11. Adjust the brew timer as required. See 
Adjusting Brew Volumes. Repeat steps 9 & 10.
12. The brewer is now properly adjusted to brew coffee.
This equipment must be installed to comply with the Basic Plumbing Code of the Building
Officials and Code Administrators International, Inc. (BOCA) and the Food Service Sanitation
Manual of the Food and Drug Administration (FDA).
PLUMBING REQUIREMENTS(cont.)
10067.3 070102
Plumbing Hook-up
1. Make certain the 3/8" female flare fittings on the short tube from the outlet of strainer (supplied) is securely
attached to the male fitting at the bottom rear of the brewer.
2. Flush the water line and securely attach it to the 3/8" male flare fitting on the inlet of the strainer.
3. Turn on the water supply.
4. Inspect the connection for leaks.