PROGRAMMING THE BREWER (cont.)
PROGRAMMING FUNCTIONS - LEVEL  2 (cont.)
SET TEMP
This function allows the operator to adjust the brew 
water temperature in the tank.  This also sets the hot 
water faucet dispense temperature.
Procedure for setting the Set Temp
Range: 185° to 205° F (85° to 96° C)
1.  Press and hold the right hidden button until the 
display reads SET LANGUAGE. Press the right 
hidden button until the display reads SET TEMP.  
2. Using 
(-) and (+), adjust the brew and faucet tem-
perature.
3.  When fi nished, press and release DONE to save 
the new setting and to advance to the next function 
screen,  READY DEGREE. Press and release the 
ON/OFF pad to exit programming and return to the 
MAIN SCREEN.
BREW
A
BREW
B
BREW
C
SET TEMP: 200°
(-)    DONE    (+)
READY DEGREE 5°
(-)    DONE    (+)
P3090