Bunn Dual TF DBC Manual De Usuario

Descargar
Página de 56
Page 34
Procedure to set ready temperature:
1.  Press and hold upper right hidden switch until the 
display reads UNITS. Release switch.  Continue to 
press and release switch until the display reads 
SET READY.
2.  To adjust the ready temperature, press the (-) 
button to decrease, or (+) to increase the ready 
temperature.
3.  When fi nished, press and release DONE to save 
the new setting, exit the SET READY function and 
advance to the next function screen, REFILL. An-
other alternative is to press and release either of 
the ON/OFF switches located on the front switch 
panel to exit the SET READY function and return 
to the MAIN SCREEN.
PROGRAMMING THE BREWER (cont.)
REFILL - Range: 0 to 155
 
This function allows the operator to adjust the 
sensitivity of the refi ll circuit. This is mainly a trouble-
shooting feature. Water in different geographical loca-
tions can have different conductivities. By adjusting 
the sensitivity of the refi ll circuit, this will allow the 
brewer to operate under various water conditions.
3.  When fi nished, press and release DONE to save 
the new setting, exit the SET TEMP function and 
advance to the next function screen,  SET READY. 
Another alternative is to press and release either 
ON/OFF switch located on the front switch panel 
to exit the SET TEMP function and return to the 
MAIN SCREEN.
SET READY - Range: 185˚F (85˚C) to 203˚F (95˚C)
 
This function allows the operator to set the mini-
mum temperature allowable to start a brew cycle. The 
range can be from 185˚F (85˚C) to within 2˚F (-1.7°C) 
of the SET TEMP. The water must be at the SET READY 
temperature or higher for the display to indicate READY 
TO BREW
. If brew lockout is enabled, the brewing pro-
cess will not start below this READY temperature.
NOTE: The upper limit for SET READY temperature 
is 2˚F (-1.7°C) less than the water temperature (SET 
TEMP) setting.
SET TEMP  (cont.)
P2721
SET READY: XXX°
 (-)  DONE  (+)
Procedure to set the sensitivity threshold of the 
refi ll circuit:
NOTE: 
Make sure the water in the tank is touching 
the refi ll probe.
1.  Press and hold upper right hidden switch until the 
display reads UNITS. Release switch.  Continue to 
press and release switch until the display reads 
REFILL and shows a number on both sides of the 
word.
2.  To adjust the threshold setting, press (-) to de-
crease, or (+) to increase the setting.
NOTE: Always make sure that the number on the right 
is larger than the number on the left when water is in 
contact with the refi ll probe in the tank.
3. When 
fi nished, press and release DONE. This saves 
the new setting and advances to the next function 
screen, L SPRY OZ/M. Another alternative is to 
press and release either of the ON/OFF switches 
located on the front switch panel to exit REFILL 
and return to the MAIN SCREEN.
SPRAY OZ/M
 
This function allows the operator to view or to enter 
the actual fl ow rate coming out of the sprayhead. This 
is NOT used to change the actual fl ow rate, but to tell 
the internal controller how fast the water is fl owing. 
The unit of measure is ounces per minute (Oz/M).
P2721
XXX REFILL -> XXX
 (-)  DONE  (+)
P2721