Bunn Dual TF DBC Manual De Usuario

Descargar
Página de 56
Page 38
PROGRAMMING THE BREWER (cont.)
EXIT TO
NEXT FUNCTION
SCREEN
EXIT TO
NEXT FUNCTION
SCREEN
PRESS AND RELEASE
® SYMBOL
PRESS AND RELEASE
® SYMBOL
NEXT COMPONENT
TO BE TESTED
TEST OUTPUTS?
NO                     YES
TEST SWITCHES?
NO                     YES
LEFT BREW VALVE
ON      NEXT      OFF
125.0 KHZ.    4
4     125.0 KHZ.        
NOTHING PRESSED
TEST FREQUENCY?
NO                     YES
SERVICE TOOLS?
NO                     YES
P2610
5. When fi 
nished, press NEXT to advance counter 
screens until the display reads BREW COUN-
TERS.  
Press and release NO  to advance to the 
next function screen, or press  and release either 
ON/OFF switch on the front switch panel to exit 
the BREW COUNTERS function and return to the 
MAIN SCREEN.  
FUNNEL DETECT (optional)
 
This function allows the operator to prevent the 
start of a brew cycle if a Smart Funnel is not positioned 
correctly in the funnel rails.
Procedure to set funnel detect:
1.  Press and hold the upper right hidden switch until 
display reads UNITS. Release the switch. Continue 
to press and release switch until display reads 
FUNNEL DETECT.
2.  NO or YES should be fl ashing to indicate the cur-
rent setting.
4. Select 
YES to prevent brewing if a Smart Funnel is 
not correctly situated in the rails.  If this function 
is activated and a brew cycle is attempted with the 
funnel not properly situated, the display will read,  
FUNNEL NOT IN PLACE, until one is in place.
5. Select 
NO to allow brewing without a Smart Fun-
nel in place. This is selected when brewing with a 
funnel other than a Smart Funnel (a regular brew 
funnel).
6.  When fi nished, press and release DONE. This will 
retain the changes, exit this function screen and 
advance to the next. Another alternative is to press 
either ON/OFF switch located on the front switch 
panel to exit the FUNNEL DETECT and return to 
the MAIN SCREEN.
P2721
FUNNEL DETECT ?
 NO 
DONE 
YES
BREW COUNTERS (cont.)
SERVICE TOOLS
 
This function allows the testing of individual com-
ponents and the ability to check switches for proper 
function. This function also tests the Soft Heat
®
 server's 
status on the brewer (in place or removed), and the 
funnel sensor coil's frequency (diagnostic tool for 
troubleshooting purposes only).
Testing individual components (outputs):
 
This will allow the operator to test the operation 
of individual components and outputs of the brewer.  
The components that can be individually tested are as 
follows:
Left Brew Valve
Left Bypass Valve
Left Funnel Lock
Left Server
Right Brew Valve
Right Bypass Valve
Right Funnel Lock
Right Server
Refi ll Valve
Tank Heaters
Heater Contactor
35058.1 071205