Bunn ITCB Manual De Usuario

Descargar
Página de 79
Page 50
PROGRAMMING THE BREWER (cont.)
PROGRAMMING FUNCTIONS - LEVEL  2 (cont.)
CALIBRATE FLOW
This function allows the operator to enter the actual fl ow 
rate of the sprayhead and the dilution by dispensing 
both separately for one minute. The volumes are then 
entered into the brewer.
Procedure to calibrate the sprayhead fl ow rate:
1.  Place a container, accurately graduated and with 
a minimum capacity of 60 ounces (1.77 liters), 
beneath the funnel.
2.  Press and hold the right hidden button until the 
display reads SET LANGUAGE. Press the right 
hidden button until the display reads CALIBRATE 
FLOW
.  
3. Press and release YES to advance to the SPRAY 
HEAD CAL function screen. (Pressing NO  in the 
CALIBRATE FLOW screen will advance to the next 
function screen, BREW COUNTERS).
4.  Press and release the YES pad. The display should 
read CONTAINER READY?  If the container is under 
the funnel, press YES.  
5.  The display should read CALIBRATE SPRAY.  Press 
and release START to begin the sprayhead fl ow for 
calibration. The display should read CALIBRATE 
SPRAY...60 SEC TO FINISH.
  The 60-second timer 
on the display will count down to zero. When the 
counter reaches zero, the display will change to 
SPRAY HD OZ/M, along with a number.
6.  Measure the amount of water in the container and 
use the (-) and (+) pads to adjust the amount of 
the display to match the amount in the container. 
Then press DONE.
7.  The display should now read NEW SPRAY FLOW
along with the correct fl ow rate of the sprayhead.  
After about 5 seconds, the display will return to the  
CALIBRATE FLOW 
screen.
8.  To exit the CALIBRATE FLOW function and advance 
to the next function screen, press and release NO.  
To exit programming, press and release the ON/OFF 
button to return to the MAIN SCREEN.
P2879
BREW
A
BREW
B
BREW
C
BREW
A
BREW
B
BREW
C
BREW
A
BREW
B
BREW
C
BREW
A
BREW
B
BREW
C
BREW
A
BREW
B
BREW
C
CALIBRATE FLOW?
NO               YES
SPRAY HEAD CAL
NO               YES
CALIBRATE FLOW?
NO               YES
CONTAINER READY?
QUIT              YES
CALIBRATE SPRAY
QUIT            START
CALIBRATE SPRAY
60 SEC TO FINISH
SPRAYHD  OZ  XX.X
(-)    DONE    (+)
NEW SPRAY FLOW
XX.X  OZ/M 
PRESSING NO WILL
ADVANCE TO
BREW COUNTERS
PRESSING NO WILL
ADVANCE TO
BREW COUNTERS
5 SEC.
36748 101505