Bunn TWF Manual De Usuario

Descargar
Página de 32
Page 16
P2198.50
FIG. 4 ICED TEA BREW SOLENOID VALVE
Location:
Viewing the brewer from the rear, the iced tea brew
solenoid valve is mounted in the center of the mount-
ing bracket.
Test Procedures:
1. Disconnect the brewer from the power source.
2. Disconnect the white/violet and white/blue wires
from the iced tea brew solenoid valve. With the
TEA/OFF/COFFEE switch in the "TEA" position press
the START switch.
3. With  a  voltmeter,  check  the  voltage  across  the
white/violet  and  white/blue  wires.  Connect  the
brewer to the power source. The indication must
be 120 volts ac for two wire 120 volt models and
three wire 120/208 volt models.
4. Disconnect the brewer from the power source.
If voltage is present as described, proceed to #5
If voltage is not present as described, refer to 
Wiring
Diagrams and check brewer wiring harness.
5. Check for continuity across the iced tea brew so-
lenoid valve coil terminals.
If  continuity  is  present  as  described,  reconnect  the
white/violet  and  white/blue  wires  from  the  iced  tea
brew timer.
If continuity is not present as described, replace the
solenoid valve.
6. Check the iced tea solenoid valve for coil action.
Connect the brewer to the power source. With TEA/
OFF/COFFEE  switch  in  the  "TEA"    position  press
the START switch and listen carefully in the vicin-
ity of the solenoid valve for a "clicking" sound  as
the coil magnet attracts.
7. Disconnect the brewer from the power source.
If the sound is heard as described and water will not
pass through the solenoid valve, there may be a block-
age in the water line before the solenoid valve or, the
solenoid valve may require inspection for wear, and
removal of waterborne particles.
If  the  sound  is  not  heard  as  described,  replace  the
solenoid valve.
Removal and Replacement:
1. Remove all wires from solenoid valves.
2. Turn off the water supply to the brewer.
3. Disconnect the water lines to and from the sole-
noid valves.
4. Remove  the  two  #8-32  keps  nuts  holding  the
mounting bracket to the brewer base.
5. Lift out the bracket.
6. Remove the two #10-32 slotted-head screws hold-
ing the iced tea brew solenoid valve to the mount-
ing bracket.
7. Securely  install  the  new  iced  tea  brew  solenoid
valve to the mounting bracket.
8. Attach the mounting bracket to the brewer base.
9. Securely  fasten  the  water  lines  to  and  from  the
solenoid valves.
10. Refer to Fig. 5 when reconnecting the wires.
SERVICE (cont.)
BREW SOLENOID VALVE (ICED TEA)
FIG.5 SOLENOID VALVE TERMINALS
P1364
HOT COFFEE
BREW SOLENOID
ICED TEA BREW
SOLENOID
DILUTION
SOLENOID
WHI/BLU to Dilution
Solenoid
WHI/VIO to Dilution
Solenoid
10510 081599