TL1 - WHI/RED to Hot Coffee Solenoid and
         WHI/RED to TEA/OFF/COFFEE Switch
TL2 - WHI to Power Cord (120V Models) or
         WHI to Terminal Block (120/208V Models)
TL3 - WHI/ORN to START Switch
TL4 - WHI/GRN to Hot Coffee Solenoid
TL5 - WHI/YEL to START Switch
FIG. 9 DIGITAL TIMER WIRING
P2037
SERVICE (cont.)
DIGITAL  BREW  TIMER  (HOT  COFFEE  -  Late
Models)(cont.)
1. Modifying brew volumes. To modify a brew vol-
ume, first check that the SET/LOCK switch is in the
“SET” position on the circuit board.
To increase a brew volume, place the TEA/OFF/
COFFEE switch in the “COFFEE” position, press and
hold  the  START  switch  until  three  clicks  are  heard.
Release  the  switch  and  press  it  again  one  or  more
times. (Failure to release the switch within two sec-
onds after the third click causes the volume setting to
be aborted and previous volume setting will remain in
memory.) Each time the switch is pressed, two sec-
onds  are  added  to  the  brew  time  period.  Allow  the
brew cycle to finish in order to verify that the desired
volume has been achieved.
To decrease a brew volume, place the TEA/OFF/
COFFEE switch in the “COFFEE” position, press and
release the START switch once for every two-second
interval to be removed from the total brew time pe-
riod; then immediately press and hold down the START
switch until three clicks are heard. Release the switch.
(Failure to release the switch within two seconds af-
ter  the  third  click  causes  the  volume  setting  to  be
aborted  and  previous  volume  setting  will  remain  in
memory). Allow the brew cycle to finish in order to
verify that the desired volume has been achieved.
2. Setting  brew  volumes.    To  set  a  brew  volume,
first check that the SET/LOCK switch is in the “SET”
position on the circuit board. Place the TEA/OFF/COF-
FEE switch in the “COFFEE” position, press and hold
the START switch until three distinct clicks are heard
and  then  release  the  switch.  (Failure  to  release  the
switch within two seconds after the third click causes
the  volume  setting  to  be  aborted  and  previous  vol-
10510  071000
ume setting will remain in memory.)
View  the  level  of  the  liquid  being  dispensed.  When
the desired level is reached, turn the TEA/OFF/COF-
FEE switch to “OFF”.
NOTE:  Several ounces of water will continue to sy-
phon  from  the  tank  after  turning  the  switch  “OFF”.
The brewer remembers this volume and will continue
to brew batches of this size until the volume setting
procedure is repeated.
NOTE: When brewing coffee, volume will decrease due
to absorption by the coffee grounds.
3. Setting  programming  disable  feature.  If  it  be-
comes necessary to prevent anyone from changing
brew time once programmed, you can set the SET/
LOCK  switch  to  the  “LOCK”  position.  This  will  pre-
vent  any  further  programming  until  switch  is  once
again put into the “SET” position.