TROUBLESHOOTING (cont.)
PROBLEM
PROBABLE CAUSE
REMEDY
Brew cycle(s) will not start (cont.)
Brew water is not hot
Dilution  (Iced  Tea)  cycle  will  not
start
6. Brew Timer
A) Iced Tea
B) Hot Coffee
7. Brew Solenoid Valve
A) Iced Tea
B) Hot Coffee
8. Internal Flow control  (.195 GPM)
(Hot Coffee Only)
1. Limit Thermostat
CAUTION - Do not eliminate or by-
pass  limit  thermostat.  Use  only
BOM 
replacement 
part
#29329.1000
2. Thermal Fuse
CAUTION - Do not eliminate or by-
pass thermal fuse.
3. Control Thermostat
4. Tank Heater
1. TEA/OFF/COFFEE Switch
Refer to
 Service -  Brew Timer (Iced
Tea)  for  testing  procedures.  See
page 20 or 21
Refer to
 Service  - Brew Timer (Hot
Coffee) for testing procedures. See
page 17 or 18
Refer  to 
Service  -  Brew  Solenoid
Valve (Iced Tea) for testing proce-
dures. See page 16
Refer  to 
Service-  Brew  Solenoid
Valve (Hot Coffee) for testing pro-
cedures. See page 15
(A) Direction of flow arrow must be
pointing towards brewer.
(B)  Remove  the  flow  control  and
check for obstructions. Clear or re-
place.
Refer to 
Service - Limit Thermostat
for testing procedures. See page 25
Refer to 
Service - Thermal fuse for
testing procedures. See page 29
Refer to 
Service - Control Thermo-
stat  for  testing  procedures.  See
page 23
Refer to 
Service - Tank Heater for
testing procedures. See page  28
Refer to 
Service - TEA/OFF/COFFEE
Switch for testing procedures. See
page 26
10510  071000