TROUBLESHOOTING (cont.)
Fill  or  refill  does  not  shut  "OFF"
(ON/OFF Switch "ON")
Fill  or  refill  does  not  shut  "OFF"
(ON/OFF Switch "OFF")
PROBABLE CAUSE
REMEDY
PROBLEM
1. Lime build up on probe (CDBC-
APS/TS/TSR & CEZ-APS/TS/TSR)
2a.  Water  Level  Probe  Sensing
System (CDBC-APS/TS/TSR)
2b.  Water  Level  Probe  Sensing
System (CEZ-APS/TS/TSR)
3.  Refill  valve  or  control  board
(CDBC-APS/TS/TSR & CEZ-APS/
TS/TSR)
1.  Refill  valve  or  control  board
(CDBC-APS/TS/TSR & CEZ-APS/
TS/TSR)
Remove Probe and check for lime
deposits on tip. Clean and reinstall.
A) Disconnect the brewer from the
power source. Disconnect the J3
connector from the control board.
Check for continuity from the nut
on top of the level probe to pin 1 of
the  plug,  continuity  should  be
present.  Pull  the  temperature
probe up about an inch from the
grommet.  Check  for  continuity
from  the  outside  surface  of  the
temperature probe and pin 4 of the
plug, continuity should be present.
Connect the J3 plug to the control
board and proceed to step 3.
B) Disconnect the brewer from the
power source. Disconnect the J5
connector from the control board.
Check for continuity from the nut
on top of the level probe to pin 5 of
the  plug,  continuity  should  be
present.  Pull  the  temperature
probe up about an inch from the
grommet.  Check  for  continuity
from  the  outside  surface  of  the
temperature probe and pin 2 of the
plug, continuity should be present.
Connect the J5 plug to the control
board and proceed to step 3.
Press ON/OFF switch to "ON" (In-
dicator lamp should be lit). If wa-
ter  continuously  flows  out  of  air
vent tube, disconnect the brewer
from  the  power  source.  If  water
flow  stops,  replace  the  control
board. If water flow does not stop,
repair  or  replace  the  refill  sole-
noid. (See page 30)
If water continuously flows out of
air  vent  tube,  disconnect  the
brewer from the power source. If
water flow does not stop, repair or
replace  the  refill  solenoid.  If  the
valve  closes  when  power  is  re-
moved, replace the control board.
(See pages 21 & 22)