Bunn ITB/ITCB Manual De Usuario

Descargar
Página de 30
9
DIAGNOSTICS
PROBABLE CAUSE
REMEDY
MESSAGE
Temperature Too Low
Heating Time Too Long
Fill Time Too Long
Temp Sensor Out Of Range, Check 
For Bad Connections
Temp Sensor Out Of Range, Check 
Wire For Shorts
1. Water temperature in the tank 
does not meet the ready tempera-
ture.
1. Tank Heater failure.
2. Control Board/Thermistor fail-
ure
1. Water shut off to brewer
2. Supply line too small or ob-
structed
3. Inlet Solenoid failure
4. Control Board Failure
5. ON/OFF switch is OFF
1. Temperature Sensor Probe 
open
1. Temperature Sensor Probe 
wire(s) shorted
A)  Wait for the brewer to heat to 
the proper temperature.
B) Disable the BREW LOCKOUT 
function.  Refer to programming 
section for procedure.
Replace or repair as needed
Replace or repair as needed
Check water supply shut-off
Replace or repair as needed
Replace or repair as needed
Replace or repair as needed
Turn switch ON
Replace or repair as needed
Replace or repair as needed
42461 0911809