Bunn CDS-3 Manual De Usuario

Descargar
Página de 60
27
R2
2
FIG. 9 CIRCUIT BREAKER
P1342
SERVICE (cont.)
CIRCUIT BREAKER
Location:
The circuit breaker is located inside the dispenser 
on the upper left side of the component bracket.
Test Procedures:
1.  Disconnect the dispenser from the power source.
2.  Remove the wires from the circuit breaker.
3.  Check for continuity between the terminals. Conti-
nuity must be present between the terminals.
If continuity is present as described the circuit breaker 
is functioning properly.
If continuity is not present as described, press the reset 
button and repeat step #3, if continuity is not present 
as described, replace the circuit breaker.
Removal and Replacement:
1.  Remove the four #8-32 locking screws securing 
the component bracket to the chassis.
2.  Tip the top of the component bracket forward far 
enough to allow access to the rear of the circuit 
breaker.
3.  Remove the wires from the circuit breaker.
4.  Compress the clips on the back side of the com-
ponent bracket and gently push the circuit breaker 
through the opening in the component bracket.
FIG. 10 CIRCUIT BREAKER TERMINALS
P1330
5.  Push the new circuit breaker into the opening in 
the  component  bracket  until  the  clips  snap  into 
position.
6.  Reconnect the wires to the circuit breaker.
7.  Position  the  component  bracket  in  chassis  and 
secure with four #8-32 locking screws. 
8.   Refer to Fig. 10 when reconnecting the wires.
27646 122200
RED from Transformer
RED from Main Harness