Bunn C Manual De Usuario

Descargar
Página de 32
Page 21
SERVICE (cont.)
TANK HEATER (Cont.)
c) 200 to 230 volts ac for two wire 200 or 230 volt
models.
3.
Disconnect the brewer from the power source.
If voltage is present as described, proceed to #4
If  voltage  is  not  present  as  described,  refer  to  the
Wiring Diagrams and check wiring harness.
4.
Disconnect the black wire and the white or red
wire from the tank heater terminals.
5.
Check for continuity across the tank heater termi-
nals.
If  continuity  is  present  as  described,  reconnect  the
wires, the tank heater is operating properly.
If continuity is not present as described, replace the
tank heater.
NOTE-  If  the  tank  heater  remains  unable  to  heat,
remove and inspect heater for cracks in the sheath.
Removal and Replacement:
1.
Disconnect  the  water  supply  tube  from  the  fill
basin.
2.
Remove  the  tank  inlet  fitting  securing  the  fill
basin to the tank lid, remove fill basin and tank
inlet gasket. Set all three parts  aside for reassem-
bly.
3.
On brewers with faucet shut-off water supply to
the  brewer  and  disconnect  the  inlet  and  outlet
water lines to the faucet coil assembly.
4.
Disconnect the black wire on the limit thermostat
from the tank heater switch. On late model brew-
ers also disconnect the blue wire from the limit
thermostat  to the control thermostat.
5.
Disconnect the black wire and the white or red
wire from the tank heater terminals.
6.
Remove sprayhead and the  hex nut securing the
sprayhead tube to the hood.  Set aside for reas-
sembly.
7.
Remove the eight #8-32 nuts securing the tank
lid to the tank.
8.
Remove  the  tank  lid  with  limit  thermostat,
sprayhead tube, tank heater, coil assembly and
control thermostat w/bracket (early models only).
9
Remove  the  two  hex  nuts  securing  the  tank
heater to the tank lid. Remove tank heater with
gaskets and discard.
10. Install new tank heater with gaskets on the tank
lid and secure with two hex nuts.
11. Install tank lid with limit thermostat, sprayhead
tube, tank heater, coil assembly (brewers with
faucet) and control thermostat with bracket (early
brewers only) using eight #8-32 hex nut.
12. Reconnect the inlet and outlet water lines to the
faucet coil assembly.
13. Secure sprayhead tube to hood using a  hex nut.
14. Install sprayhead.
15. Reconnect the wires to the limit thermostat, tank
heater and control thermostat. See limit thermo-
stat and control thermostat sections in this manual
when reconnecting wires.
16. Install fill basin, secure with tank inlet fitting and
gasket. Insert water supply line through grom-
met in fill basin.
17. Refer to the illustration below when reconnecting
the tank heater wires.
P1168
10841 071000
WHI to Terminal
Block (White Insert on
120V Two Wire
Models)
RED to Terminal
Block (Red Insert on
120/240V Threee wire
Models or 200V and
230V Two Wire
Models)
BLK to Control
Thermostat (Brewers
W/Out Faucet) Thermal
Cut-Off to BLK from
Control Thermostat
(Brewers W/Faucet