CEZ-APS/TS/TSR ADJUSTMENTS & OPTIONAL SETTINGS
IMPORTANT: The tank must be full and fill so-
lenoid shut off prior to making these adjust-
ments.
Adjusting Brew Volumes
The brewer is factory set to deliver 64 ounces
± 2 for each brew cycle.
BREW VOLUME SET-UP: Use the following steps
when the setting is unknown or a different circuit
board is being installed.
1. Place an empty funnel in the funnel rails and
an empty server or graduated vessel be-
neath the funnel.
2. Place the "ON/OFF" switch in the "ON", upper
position.
3. Press and hold the brew start button until
you hear the brew solenoid click on-and-off
three times (approximately 5 seconds). Re-
lease the button.
4. Allow the cycle to continue until the desired
amount of water is dispensed and then turn
"OFF" the brewer.
The brewer is now set to dispense this amount
of water for each subsequent brew cycle.
To increase the amount of water for each
brew cycle place an empty funnel in the funnel
rails and an empty server or graduated vessel
beneath the funnel. Place the "ON/OFF" switch in
the "ON", upper position. Press and hold the
"BREW" switch until you hear the solenoid click
on-and-off three times (approximately 5 sec-
onds), then release the "BREW" switch. Momen-
tarily press and release the "BREW" switch once
for each ounce (approximate) of water to be
added to the prior setting and allow the brew
cycle to finish.
To decrease the amount of water for each
brew cycle place an empty funnel in the funnel
rails and an empty server or graduated vessel
beneath the funnel. Place the "ON/OFF" switch
in the "ON", upper position. Momentarily press
and release the "BREW" switch once for each
ounce (approximate) of water to be removed
from the existing setting. Press and hold the
"BREW" switch until you hear the solenoid click
on-and-off three times (approximately 5 sec-
onds), then release the "BREW" switch and al-
low the cycle to finish.
P1864
P1865
29253 071599