SERVICE (CONT.)
Compressor (Cont.)
Removal and Replacement:
Compressor Relay: Refer to FIG. 8
1.  Remove the terminal cover (1)
2.  Disconnect the white wire from the compressor 
relay.
3.  Pull relay (2) off of the compressor pins and discard.
4.  Push new relay onto the compressor pins.
5.  Refer to Fig. 9 and reconnect the wires.
6.  Reinstall terminal cover (1).
Compressor Thermal Overload Protector: Refer to 
FIG. 8
1.  Remove terminal cover (1).
2.  Disconnect the BLU/BLK wire of the harness from 
the thermal overload protector.
3.  Remove relay (2).
4.  Remove overload protector (3) and discard overload 
protector.
5.  Install new overload protector (3) on to the com-
pressor.
6.  Install relay (2).
7.  Refer to Fig. 10 and reconnect the thermal overload 
protector wires.
8.  Reinstall terminal cover (1).
Compressor Assy:
NOTE: Before removal of any refrigeration component 
the refrigerant in the system must be reclaimed by a 
licensed refrigeration repair person.
NOTE: When replacing the compressor it is recom-
mended that the dryer also be replaced.
1.  Disconnect the tubes from the condenser and the 
accumulator.
2.  Disconnect the compressor wiring harness from 
the dispenser main wiring harness.
3.  Remove the four .25-20 keps nuts and washers 
securing the compressor to the chassis. Set nuts 
and washers aside for reassembly.
4.  Disconnect and remove the transformer.
5.  From the right side of the dispenser lift the com-
pressor assembly over the four studs in the chassis 
and remove compressor.
WHI Wire
BLU/BLK Wire
FIG. 9 RELAY TERMINALS
FIG. 10 THERMAL OVERLOAD PROTECTOR 
TERMINALS
Plugs into Relay
6.  Install new compressor over the four studs in the 
dispenser chassis with the fill valve to the right side 
of the dispenser.
7.  Secure compressor to the dispenser chassis using 
four .25-20 keps nuts and washers.
8.  Reconnect tubes from the condenser and the ac-
cumulator to the compressor.
9.  Reinstall transformer.
10. Evacuate the system.
11. Recharge 120V and 230V system with:
JDF-2S - 9 oz. Type R134A refrigerant.
 
 
Design Pressures: High 255 - Low 36 psi
JDF-4S & 4D - 10 oz. Type R134A refrigerant.
 
 
Design Pressures: High 335 - Low 88 psi
NOTE: The charging of the system must be done by a 
licensed refrigeration repair person.
NOTE: Refer to Wiring Diagrams when reconnecting 
wires to Compressor, Thermal Overload Protector and 
Start Relay.