Bunn JDF-4D Manual De Usuario

Descargar
Página de 57
38
SERVICE (CONT.)
EMI Filter (all Models)
FIG. 49 EMI FILTER
Location:
 
The EMI Filter is located on the electrical component 
mounting bracket on the lower front of the dispenser 
behind the splash panel.
Test Procedure:
1.  Disconnect the dispenser from the power source.
2.  Disconnect the two black wires and two white wires 
on the EMI Filter from the power cord and the main 
wiring harness.
3.  Check for resistance between the two black leads 
on the EMI Filter.
If resistance is present as described the EMI Filter is 
operating properly.
If resistance is not present as described, replace the 
EMI Filter.
Removal and Replacement:
1.  Disconnect the wires from the EMI Filter.
2.  Remove the two #8-32 screws and nuts securing 
the EMI Filter.
3.  Remove and discard EMI Filter.
4.  Install new EMI Filter using two #8-32 screws and 
nuts to secure EMI Filter to its former location.
5.  Refer to Fig. 50 when reconnecting the wires.
FIG. 50 EMI FILTER CONNECTORS
118.0 kΩ - 118.5 kΩ
Across either pair
JDF-4S shown
49179  110613