Bunn JDF-4D Manual De Usuario

Descargar
Página de 57
41
SERVICE (CONT.)
Rectifier (JDF-2S, JDF-4S)
Removal and Replacement:
1.  Disconnect the wires from the rectifier.
2.  Remove the #10-32 screw securing the rectifier.
3.  Remove the rectifier and discard.
4.  Secure new rectifier with #10-32 screw.
5.   Refer to Fig. 56 and reconnect the wires. 
BLU from Door Harness (+)
WHI/GRN to Transformer (~ AC)
WHI/BLK to Transformer (~ AC)
WHI from Door Harness (-)
FIG. 56 RECTIFIER TERMINALS
FIG. 55 RECTIFIER
Location:
 
The rectifier is located on the electrical component 
mounting bracket on the lower front of the dispenser 
behind the splash panel.
Test Procedures:
1.  Disconnect the dispenser from the power 
source.
2.  Remove the blue wire and the white wire from the 
rectifier.
3.  Check the voltage across the (+) and (-) terminals 
on the rectifier with a voltmeter. Connect the dis-
penser to the power source. The indication must 
be approximately 24 volts dc.
4.  Disconnect the dispenser from the power 
source.
If voltage is present as described, the rectifier is op-
erating properly.
If voltage is not present as described, refer to the 
dispenser wiring diagram and check the wiring back 
to the transformer.
12
11
9
8
7
49179  110613